-
Feb 04,2020
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Feb 10,2020
WHAT IS HARMONIC FILTERING? To understand the purpose of harmonic filtering, it helps to understand what harmonics are. The voltage of a standard 50Hz Alternating Current(AC) power supply swings between positive and negative 50 times a second, following a neat sine-wave. Linear AC electrical loads such as heaters or incandescent lights draw a current that follows this same sine-wave. The graph abo...
read more
-
Feb 12,2020
A capital investment in power factor correction(STATCOM or SVC) and harmonic filtering equipment can result in a healthy return of investment –depending on the utility’s demand rate structure, production quality cost due to harmonics and voltage fluctuations in the distribution system. ZDDQ Electric power quality correction products are part of the solution. Most utilities charge for peak electric...
read more
-
Feb 21,2020
Medium Voltage STATCOM-Dynamic Reactive Compensation -----Providing stability, security, and reliability to the grid Installing a STATCOM at one or more suitable points on the network is a powerful and cost effective method to increase grid transfercapability and enhance voltage stability. What is a STATCOM? A STATCOM (or Static Synchronous Compensator) is a voltage regulating device. It is based ...
read more
-
Feb 25,2020
ZDDQ has come back to factory and start to work Since Feb.18th. The factory will carry out the strict measures to maintain the normal production to meet clients' orders. In 2020, we will focus on low voltage and medium voltage power qualit improvement and power factor correction. In low voltage field, we will push on R&D of Active power filter, and provide perfect service for clients.We have b...
read more
-
Feb 29,2020
The ubiquity of synchronous generation should not be assumed in highly renewable power systems. Various problems may consequently arise, not least of which are the difficulties entailed in maintaining regional reactive power balance. Offering a potential solution to such problems, modern renewable generator technologies offer controllable reactive power resources. As many of these generators will ...
read more
-
Mar 17,2020
China's economy According to China Daily China's economy is gradually returning back to normal, as major industrial companies outside of Hubei province have resumed work at a rate of more than 90 percent, China's top economic regulator said on Tuesday. The nonferrous metal industry's electricity consumption has reached normal level last year, and power consumption in the medical, chemical and elec...
read more
-
Mar 23,2020
Overview of Active Power Filter APF-1000 APF-1000 Active power filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensation, and the proportion of compensation capacity by harmonic, reactive power, and three-phase unbalance can also be set, comprehensively solving the problem of ...
read more
-
Mar 28,2020
Power quality “Power quality” can seem to be a pretty abstract term – how does one judge the quality of such an unseen commodity as electricity? But, as commercial and industrial facility managers know, good power quality can boost both productivity and employee safety, while poor power quality can mean a drain on the bottom line, thanks to damaged equipment, lost productivity and product spoilage...
read more
-
Apr 03,2020
Power factor correction Connected equipment (transformers, motors, air-conditioning, refrigerators, etc.) cause a phase angle between current and voltage.When the current is phase-shifted, it takes more current to deliver the same amount of active power. Impact of reactive power • Transmission equipment has to be sized for the apparent power, yet only active power is useful • Increased losses in t...
read more
-
Apr 18,2020
Power quality problems and Industry background Dynamic reactive power, lower power factors, and higher harmonic content are common power quality problems in the CNC industry. Major contamination sources of power quality include the punching machines,welding machines. When harmonics occur, dynamic reactive current and 3-phase imbalance are produced. During the CNC period, the power factor of arc fu...
read more
-
May 26,2020
Power Factor: Power factor correction(Cosφ) Benefits of power factor correction Improves system power factor Reduces network losses Avoid penalty charges from utilities for excessive consumption of reactive power Reduces cost and generates higher revenue for the customer Increases system capacity and saves cost on new installations Improves voltage regulation in the network Increases power availab...
read more
-
Jun 19,2020
Global compensation Where a load is continuous and stable, global compensation can be applied Principle The capacitor bank is connected to the busbars of the main LV distribution board for the installation, and remains in service during the period of normal load. Advantages The global type of compensation: Reactive current still flows in all conductors of cables leaving (i.e. downstream of) the ma...
read more
-
Jul 08,2020
How to calculate Harmonic Filter In power supply systems based on alternating current (AC) -- such as the main power distribution network from electric utilities -- non-linear loads can feed some amount of power back into the wiring. This feedback typically occurs in the form of harmonics: multiples of the frequency of the original AC wave. Harmonics need to be eliminated from a power circuit by a...
read more
-
Sep 24,2020
480V power quality solutions has the best compatibility for low voltage grid(3 phase 4 wire).ZDDQ has full series 480V devices for power quality improvement and power factor correction. 480V Active Power Filter Active Power Filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensa...
read more
-
Oct 21,2020
Our Indian Clients and African Clients has installed hybrid reactive power compensation system. After our guide, they use ZDDQ SVG mixed with Capapacitor banks based on Contactors and Thyristors. A united system of thyristor switched capacitor (TSC) and static var generator (SVG) was proposed to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. Th...
read more
-
Nov 23,2020
ZDDQ Static Var Generator SVG and Active Power Filter APF adopt dual interface of Current Transformer,which has great to facilitate new project design and adaptation to old projects. Our SVG and APF can accurately calculate the load harmonic current data and provide perfect compensation effect. For following sites, Both single module or multiple modules in parallel, Multiple active filter/SVGcabin...
read more
-
Nov 30,2020
Relations between Reactive power,power factor and penalty Power Factor penalty is spelled out in the contract between the Power Company and Industrial or Commercial customer with large three phase loads. If the contract calls for 85% Power Factor, once the customer’s power factor falls below 85%, the Power Company bills the Customer according to the agreed penalty rates. Industrial loads are mostl...
read more