-
Feb 10,2020
WHAT IS HARMONIC FILTERING? To understand the purpose of harmonic filtering, it helps to understand what harmonics are. The voltage of a standard 50Hz Alternating Current(AC) power supply swings between positive and negative 50 times a second, following a neat sine-wave. Linear AC electrical loads such as heaters or incandescent lights draw a current that follows this same sine-wave. The graph abo...
read more
-
Feb 12,2020
A capital investment in power factor correction(STATCOM or SVC) and harmonic filtering equipment can result in a healthy return of investment –depending on the utility’s demand rate structure, production quality cost due to harmonics and voltage fluctuations in the distribution system. ZDDQ Electric power quality correction products are part of the solution. Most utilities charge for peak electric...
read more
-
Feb 21,2020
Medium Voltage STATCOM-Dynamic Reactive Compensation -----Providing stability, security, and reliability to the grid Installing a STATCOM at one or more suitable points on the network is a powerful and cost effective method to increase grid transfercapability and enhance voltage stability. What is a STATCOM? A STATCOM (or Static Synchronous Compensator) is a voltage regulating device. It is based ...
read more
-
Mar 11,2020
Product Description ZDDQ Medium Voltage Metal Enclosed Capacitor and Harmonic Filter Banks are designed for industrial, commercial, and utility power systems requiring medium voltage automatic power factor correction. Standard designs are available for placement in outdoor or indoor substations (an enclosure integrity option can be added to allow for placement in publicly accessible areas) for pow...
read more
-
Apr 03,2020
Power factor correction Connected equipment (transformers, motors, air-conditioning, refrigerators, etc.) cause a phase angle between current and voltage.When the current is phase-shifted, it takes more current to deliver the same amount of active power. Impact of reactive power • Transmission equipment has to be sized for the apparent power, yet only active power is useful • Increased losses in t...
read more
-
May 26,2020
Power Factor: Power factor correction(Cosφ) Benefits of power factor correction Improves system power factor Reduces network losses Avoid penalty charges from utilities for excessive consumption of reactive power Reduces cost and generates higher revenue for the customer Increases system capacity and saves cost on new installations Improves voltage regulation in the network Increases power availab...
read more
-
Jun 06,2020
Overview A New Generation in Power Factor Correction Today's automation equipment benefits us with greater convenience as well as cost savings from higher production efficiency. However, it can also bring significant wave distortion problems to the power grid that can lead to energy loss, increasing costs and many other power quality issues. A clean and efficient power system normally generates a ...
read more
-
Jun 12,2020
What is Power Factor? Power factor is a measure of how effectively you are using electricity. Various types of power are at work to provide us with electrical energy. Here is what each one is doing. Working Power – the “true” or “real” power used in all electrical appliances to perform the work of heating, lighting, motion, etc. We express this as kW or kilowatts. Common types of resistive loads a...
read more
-
Jun 19,2020
Global compensation Where a load is continuous and stable, global compensation can be applied Principle The capacitor bank is connected to the busbars of the main LV distribution board for the installation, and remains in service during the period of normal load. Advantages The global type of compensation: Reactive current still flows in all conductors of cables leaving (i.e. downstream of) the ma...
read more
-
Jun 29,2020
The nature of transformer inductive reactances All previous references have been to shunt connected devices such as those used in normal loads, and power factor correction capacitor banks etc. The reason for this is that shunt connected equipment requires (by far) the largest quantities of reactive energy in power systems; however, series-connected reactances, such as the inductive reactances of p...
read more
-
Jul 27,2020
Overview ZD-MCJB Medium voltage automatic power factor controller and protection Unit Our R&D has developed MV automatic power factor controller and protection unit since May 2019, and has intalled in many sites an d has a very good running. Now we introduce our MV auto PF controller and protection unit officially. ZD-MCJB PF controller and protection unit is suitable for automatically adjusti...
read more
-
Aug 03,2020
Low Power Factor Operation of Induction Motor Induction Motors finds various applications in industries and household equipments. Such machine requires magnetic fields for its functioning hence, it draws magnetizing current from the source. The magnetizing current is the current that establishes the flux in the air gap of an Induction motor and this is independent of the load on the motor. It is t...
read more
-
Sep 15,2020
Leaders in Power Quality Solutions ZDDQ is one of leading manufacturers of power quality solutions from China. Here at ZDDQ we believe in creating and maintaining the highest quality power possible for our customers through an indepth understanding of power usage and electrical efficiencies. We source world’s best components to manufacture custom solutions to reduce maintenance and energy costs. N...
read more
-
Oct 30,2020
Our low voltage Static Var Generator has widely installed in many countries and has a good function and quality performance. In some countries, client use our SVG to compensate reactive power together with their capacitor banks, which is named as hybrid compensation system. In some countries, our SVG are used for power factor correction at the site where the load changes fast and frequently. And s...
read more
-
Nov 11,2020
With our best quality of our products and good relationship in the power quality field, we just received an important order for medium voltage capacitor banks. Backgroud. The rated voltage is 10kv. The total capacity is 35.4Mvar. There are individual type capacitor banks, central capacitor banks. Also there are fixed capacitor banks, and mulitipl-step automatic capacitor banks. As we know, STATCOM...
read more
-
Nov 30,2020
Relations between Reactive power,power factor and penalty Power Factor penalty is spelled out in the contract between the Power Company and Industrial or Commercial customer with large three phase loads. If the contract calls for 85% Power Factor, once the customer’s power factor falls below 85%, the Power Company bills the Customer according to the agreed penalty rates. Industrial loads are mostl...
read more
-
Dec 09,2020
The static var generator (SVG) with appropriate control method is a good solution to solve the problem of reactive power impact and harmonic pollution which is generated by the nonlinear load. A control strategy using active current separation and the current indirect control is used for SVG. The active current separation is a method for detecting the harmonic and reactive current, and then the su...
read more
-
Dec 26,2020
Power factor is the percentage of consumed power(KW) versus supplied power(KVA). This is important because a low power factor can waste energy, result in inefficient use of electrical power, and often result in higher energy bills. Power Factor Correction will improve the energy efficiency of any electrical system, but a reduction in your power bill is only available where a power company charges ...
read more