Feb 04,2020
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 10,2020
WHAT IS HARMONIC FILTERING? To understand the purpose of harmonic filtering, it helps to understand what harmonics are. The voltage of a standard 50Hz Alternating Current(AC) power supply swings between positive and negative 50 times a second, following a neat sine-wave. Linear AC electrical loads such as heaters or incandescent lights draw a current that follows this same sine-wave. The graph abo...
read more
-
Feb 12,2020
A capital investment in power factor correction(STATCOM or SVC) and harmonic filtering equipment can result in a healthy return of investment –depending on the utility’s demand rate structure, production quality cost due to harmonics and voltage fluctuations in the distribution system. ZDDQ Electric power quality correction products are part of the solution. Most utilities charge for peak electric...
read more
-
Mar 11,2020
Product Description ZDDQ Medium Voltage Metal Enclosed Capacitor and Harmonic Filter Banks are designed for industrial, commercial, and utility power systems requiring medium voltage automatic power factor correction. Standard designs are available for placement in outdoor or indoor substations (an enclosure integrity option can be added to allow for placement in publicly accessible areas) for pow...
read more
-
Mar 17,2020
China's economy According to China Daily China's economy is gradually returning back to normal, as major industrial companies outside of Hubei province have resumed work at a rate of more than 90 percent, China's top economic regulator said on Tuesday. The nonferrous metal industry's electricity consumption has reached normal level last year, and power consumption in the medical, chemical and elec...
read more
-
Mar 23,2020
Overview of Active Power Filter APF-1000 APF-1000 Active power filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensation, and the proportion of compensation capacity by harmonic, reactive power, and three-phase unbalance can also be set, comprehensively solving the problem of ...
read more
-
Apr 03,2020
Power factor correction Connected equipment (transformers, motors, air-conditioning, refrigerators, etc.) cause a phase angle between current and voltage.When the current is phase-shifted, it takes more current to deliver the same amount of active power. Impact of reactive power • Transmission equipment has to be sized for the apparent power, yet only active power is useful • Increased losses in t...
read more
-
Apr 18,2020
Power quality problems and Industry background Dynamic reactive power, lower power factors, and higher harmonic content are common power quality problems in the CNC industry. Major contamination sources of power quality include the punching machines,welding machines. When harmonics occur, dynamic reactive current and 3-phase imbalance are produced. During the CNC period, the power factor of arc fu...
read more
-
May 26,2020
Power Factor: Power factor correction(Cosφ) Benefits of power factor correction Improves system power factor Reduces network losses Avoid penalty charges from utilities for excessive consumption of reactive power Reduces cost and generates higher revenue for the customer Increases system capacity and saves cost on new installations Improves voltage regulation in the network Increases power availab...
read more
-
Jun 06,2020
Overview A New Generation in Power Factor Correction Today's automation equipment benefits us with greater convenience as well as cost savings from higher production efficiency. However, it can also bring significant wave distortion problems to the power grid that can lead to energy loss, increasing costs and many other power quality issues. A clean and efficient power system normally generates a ...
read more
-
Jun 12,2020
What is Power Factor? Power factor is a measure of how effectively you are using electricity. Various types of power are at work to provide us with electrical energy. Here is what each one is doing. Working Power – the “true” or “real” power used in all electrical appliances to perform the work of heating, lighting, motion, etc. We express this as kW or kilowatts. Common types of resistive loads a...
read more
-
Jun 19,2020
Global compensation Where a load is continuous and stable, global compensation can be applied Principle The capacitor bank is connected to the busbars of the main LV distribution board for the installation, and remains in service during the period of normal load. Advantages The global type of compensation: Reactive current still flows in all conductors of cables leaving (i.e. downstream of) the ma...
read more
-
Jun 29,2020
The nature of transformer inductive reactances All previous references have been to shunt connected devices such as those used in normal loads, and power factor correction capacitor banks etc. The reason for this is that shunt connected equipment requires (by far) the largest quantities of reactive energy in power systems; however, series-connected reactances, such as the inductive reactances of p...
read more
-
Jul 08,2020
How to calculate Harmonic Filter In power supply systems based on alternating current (AC) -- such as the main power distribution network from electric utilities -- non-linear loads can feed some amount of power back into the wiring. This feedback typically occurs in the form of harmonics: multiples of the frequency of the original AC wave. Harmonics need to be eliminated from a power circuit by a...
read more
-
Jul 27,2020
Overview ZD-MCJB Medium voltage automatic power factor controller and protection Unit Our R&D has developed MV automatic power factor controller and protection unit since May 2019, and has intalled in many sites an d has a very good running. Now we introduce our MV auto PF controller and protection unit officially. ZD-MCJB PF controller and protection unit is suitable for automatically adjusti...
read more
-
Aug 03,2020
Low Power Factor Operation of Induction Motor Induction Motors finds various applications in industries and household equipments. Such machine requires magnetic fields for its functioning hence, it draws magnetizing current from the source. The magnetizing current is the current that establishes the flux in the air gap of an Induction motor and this is independent of the load on the motor. It is t...
read more
-
Sep 15,2020
Leaders in Power Quality Solutions ZDDQ is one of leading manufacturers of power quality solutions from China. Here at ZDDQ we believe in creating and maintaining the highest quality power possible for our customers through an indepth understanding of power usage and electrical efficiencies. We source world’s best components to manufacture custom solutions to reduce maintenance and energy costs. N...
read more