-
Sep 15,2020
Leaders in Power Quality Solutions ZDDQ is one of leading manufacturers of power quality solutions from China. Here at ZDDQ we believe in creating and maintaining the highest quality power possible for our customers through an indepth understanding of power usage and electrical efficiencies. We source world’s best components to manufacture custom solutions to reduce maintenance and energy costs. N...
read more
-
Oct 04,2020
During 1st quarter in 2020, for the reason of Covid-19, Medium Voltage STATCOM projects are delayed or stopped in China. But from March, the conditions has been better and the projects status has been normal from the 2nd quarter. From the 2nd quarter to now,we have finished installatlion and commissioning of some Medium voltage Stacom projects, such as 10kv/4Mvar, 10kv/2Mvar, 35kv/12Mvar, 10k...
read more
-
Dec 18,2020
Introduction From ZDDQ professional engineers: Power systems are designed to operate at frequencies of 50 or 60Hz. However, certain types of loads produce currents and voltages with frequencies that are integer multiples of the 50 or 60 Hz fundamental frequency. These higher frequencies are a form of electrical pollution known as power system harmonics. Solution ZD-APF(Active Power Filter). This i...
read more
-
Dec 29,2020
The rising power consumption for the power quality equipment is the key driving factor for the market growth ZDDQ found according to the report: The global power quality equipment market size is projected to reach nearly USD 33.7 billion by 2028. Additionally, the market is forecasted to grow a CAGR of above 6.5% over the forecast period of 2020-2028. The key motivating force for the power efficie...
read more
-
Jan 21,2021
ZDDQ Engineers give an example for reference, An Alternator is supplying a load of 650 kW at Power factor 0.65. What size of Capacitor banks (kVAR) is required to raise the Power Factor to unity (1 or >0.95)? And how many more kW can the alternator supply for the same kVA loading when P.F improved. Supplying kW = 650 kW Original P.F = Cosθ1 = 0.65 Final P.F = Cosθ2 = 1 θ1 = Cos-1 = (0.65) = 49°...
read more
-
Feb 03,2021
HV/MV Power factor correction is directly related to the different aspects that assist the technical management of transport and distribution networks. These are: Power quality This involves the increase in the levels of voltage in substation busbars and line ends. Optimisation of the installation's cost of operation In other words, the decrease of the reactive energy and, therefore, the reduction...
read more
-
Mar 08,2021
High Voltage Power Capacitors Fields of Application INDIVIDUAL POWER FACTOR CORRECTION The power factor correction capacitor is connected directly to the terminals of the consumer and will be switched together with it. Advantages of individual capacitors at the load: • Complete control; capacitors cannot cause problems on the line during light load conditions • No need for separate switching...
read more
-
Mar 20,2021
A capacitor bank is a grouping of several identical capacitors interconnected in parallel or in series with one another. These groups of capacitors are typically used to correct or counteract undesirable characteristics, such as power factor lag or phase shifts inherent in alternating current (AC) electrical power supplies. FEATURES: Power factor correction by multi step design Standard & detu...
read more
-
Apr 12,2021
Power Quality Solutions and Energy Savings One of the most significant changes in the Power Quality industry in the past five years is the method of selling Power Quality solutions. Originally, Power Quality solutions were sold as an insurance policy to avoid potential damage from power disturbances such as transients,voltage sags, interruptions or harmonics. Today, many Power Qu...
read more
-
Apr 17,2021
Many facilities have mandates to save energy. Improving energy efficiency offers huge advantages to businesses—reducing the costs of energy and operations— and increasing sustainability. Ⅰ. Abstract Through proven methods including variable frequency drives (VFD), LED lighting and conservation methods and control, many new and existing facilities achieve the savings that they expect. However, many...
read more
-
Apr 26,2021
Power Factor Penalty An electric rate may also include additional charges when the customer has a power factor less than some preset limit, typically between 80 and 90 percent. This is called a power factor penalty since it is a penalty assessed on the customers electrical bill for lower than optimum power factor. Special devices called capacitors can be installed by either the utility or the cust...
read more
-
May 05,2021
A SECONDARY SOURCE Electricity is the set of physical phenomena associated with the presence and motion of matter that has a property of electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described by Maxwell's equations. Various common phenomena are related to electricity, including lightning, static electricity, electric heating, elect...
read more
-
May 13,2021
The climate is changing - but are you? Changes in the way you live your life - both big and small - can help you reduce your own personal carbon footprint, and also encourage policy makers to act for the good of the planet. Below is a list of several easy things you can do right now to help fight climate change. The greatest threat faced by this generation is climate change. Because without a habi...
read more
-
Oct 15,2021
Overview Rapid growth of inductive electric loads on utility networks has impacted the efficient operation of AC electrical transmission and distribution grid by increasing the need for reactive power (VAr/kVAr/MVAr) that are required to be supplied with active power. Install capacitor banks to reduce the reactive power demand from point of generation to point of use in high voltage networks. Brin...
read more
-
Jan 10,2022
ZDDQ Low Voltage Capacitor Bank for Reactive Power Compensation Reactive power compensation, is a technology that improves the power factor of the power grid in the power supply system, reduces the loss of power supply transformers and transmission lines, improves power supply efficiency, and improves the power supply environment. Therefore, the reactive power compensation device is in an indispen...
read more
-
May 27,2022
ZDDQ low voltage automatic capacitor banks improves power factor in networks with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equip...
read more
-
Jun 10,2022
Harmonic Mitigation Expert---Active Power Filter The main hazards of harmonics: Increase the load of power facilities, reduce the power factor of the system, reduce the effective capacity and efficiency of power generation, transmission and power consumption equipment, resulting in equipment waste, line waste and power loss; Causes the resonance of reactive power compensation capacitors and the am...
read more
-
Jun 30,2022
The benefits of power factor correction 1.Savings on the electricity bill Power factor correction eliminates penalties on reactive energy, decreases demand on kVA, and reduces power losses generated in the transformers and conductors of the installation. 2.Increased available power Fitting PFC equipment on the low voltage side increases the power available at the secondary of a MV/LV transformer. ...
read more