-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 18,2020
How much can be saved? Ultimately the level of energy saving achieved will be dictated by a combination of the incoming supply voltage level and the types of electrical equipment in use. The higher the supply voltage, the greater the potential to make energy savings. However different types of electrical equipment deliver different levels of energy saving for the same reduction in voltage. Voltage...
read more
-
Feb 21,2020
Medium Voltage STATCOM-Dynamic Reactive Compensation -----Providing stability, security, and reliability to the grid Installing a STATCOM at one or more suitable points on the network is a powerful and cost effective method to increase grid transfercapability and enhance voltage stability. What is a STATCOM? A STATCOM (or Static Synchronous Compensator) is a voltage regulating device. It is based ...
read more
-
Feb 25,2020
ZDDQ has come back to factory and start to work Since Feb.18th. The factory will carry out the strict measures to maintain the normal production to meet clients' orders. In 2020, we will focus on low voltage and medium voltage power qualit improvement and power factor correction. In low voltage field, we will push on R&D of Active power filter, and provide perfect service for clients.We have b...
read more
-
Feb 29,2020
The ubiquity of synchronous generation should not be assumed in highly renewable power systems. Various problems may consequently arise, not least of which are the difficulties entailed in maintaining regional reactive power balance. Offering a potential solution to such problems, modern renewable generator technologies offer controllable reactive power resources. As many of these generators will ...
read more
-
Mar 04,2020
STATCOM - Static Synchronous Compensator It is a solid-state switching converter, capable of generating or absorbing independently controllable real and reactive power at its output terminals when it is fed from an energy source. STATCOM is considered as voltage-source converter that, from a given input of dc voltage, produces a set of 3-phase ac-output voltages, each in phase with and coupled to ...
read more
-
Mar 11,2020
Product Description ZDDQ Medium Voltage Metal Enclosed Capacitor and Harmonic Filter Banks are designed for industrial, commercial, and utility power systems requiring medium voltage automatic power factor correction. Standard designs are available for placement in outdoor or indoor substations (an enclosure integrity option can be added to allow for placement in publicly accessible areas) for pow...
read more
-
Apr 03,2020
Power factor correction Connected equipment (transformers, motors, air-conditioning, refrigerators, etc.) cause a phase angle between current and voltage.When the current is phase-shifted, it takes more current to deliver the same amount of active power. Impact of reactive power • Transmission equipment has to be sized for the apparent power, yet only active power is useful • Increased losses in t...
read more
-
Apr 13,2020
Voltage Sag Voltage sag is the main problem to cause the losses of industrial production. Unpredictable outage rarely happen in many high automated process control industries. who have the good power supplies. Voltage Sag is mostly caused by thunder,but it also has other reasons. Power system cause: starting of heavy machine and short circuit fault. Unpredictable accident:traffic accident,construc...
read more
-
Apr 29,2020
STATCOM A static synchronous compensator, known as a STATCOM, is another device used to regulate the power factor in medium to high voltage applications. They operate on roughly the same principles as a synchronous compensator, however, use a voltage source converter as opposed to a rotating machine to provide dynamic Power Factor Correction. STATCOMs use IGBT switching te...
read more
-
May 13,2020
High Power STATCOM in Electricity Networks A High Power STATCOM is usually installed to support electricity networks that have a poor power factor and often poor voltage regulation. STATCOM –static synchronous compensator – is a solution often deployed by utilities or large industries to solve flicker, harmonic and dynamic reactive compensation problems in medium voltage or high voltage netw...
read more
-
May 20,2020
STATCOM STATCOM (Static Synchronous Compensator)continuously provides variable reactive power in response to voltage variations, supporting the stability of the grid. STATCOM operates according to voltage source converter (VSC) principles, combining unique PWM (pulse width modulation) with millisecond switching. STATCOM functions with a very limited need for harmonic filters, contributing to a sma...
read more
-
May 26,2020
Power Factor: Power factor correction(Cosφ) Benefits of power factor correction Improves system power factor Reduces network losses Avoid penalty charges from utilities for excessive consumption of reactive power Reduces cost and generates higher revenue for the customer Increases system capacity and saves cost on new installations Improves voltage regulation in the network Increases power availab...
read more
-
Jun 19,2020
Global compensation Where a load is continuous and stable, global compensation can be applied Principle The capacitor bank is connected to the busbars of the main LV distribution board for the installation, and remains in service during the period of normal load. Advantages The global type of compensation: Reactive current still flows in all conductors of cables leaving (i.e. downstream of) the ma...
read more
-
Jun 29,2020
The nature of transformer inductive reactances All previous references have been to shunt connected devices such as those used in normal loads, and power factor correction capacitor banks etc. The reason for this is that shunt connected equipment requires (by far) the largest quantities of reactive energy in power systems; however, series-connected reactances, such as the inductive reactances of p...
read more
-
Jul 17,2020
Problem High Electricity Bills in Steel Factory. Analysis To analyze the power quality at Steels Factory and to understand the Voltage, Current, Power Factor, Active power,Reactive power, Apparent power, THD profile and to suggest the required solution to improve Power Factor, to qualify for Utility PF incentive. Towards fulfilling the need, fixed Capacitor bank of 2400KVAr has been installed at 1...
read more
-
Jul 27,2020
Overview ZD-MCJB Medium voltage automatic power factor controller and protection Unit Our R&D has developed MV automatic power factor controller and protection unit since May 2019, and has intalled in many sites an d has a very good running. Now we introduce our MV auto PF controller and protection unit officially. ZD-MCJB PF controller and protection unit is suitable for automatically adjusti...
read more
-
Sep 08,2020
Leading Provider of Technology One of the Leading Static Var Generator manufacturing base in China Exclusive to +/-100Mvar Statcom R&D manufacture Advanced and strong R&D center Patents Owner Based on IGBT National Industry standards drafters CE Certificate 101 national patens 1 national science and technology invention award Advanced Technologies Perfect Auto-diagnosis at Starting Stage D...
read more