-
Mar 28,2020
Power quality “Power quality” can seem to be a pretty abstract term – how does one judge the quality of such an unseen commodity as electricity? But, as commercial and industrial facility managers know, good power quality can boost both productivity and employee safety, while poor power quality can mean a drain on the bottom line, thanks to damaged equipment, lost productivity and product spoilage...
read more
-
Apr 13,2020
Voltage Sag Voltage sag is the main problem to cause the losses of industrial production. Unpredictable outage rarely happen in many high automated process control industries. who have the good power supplies. Voltage Sag is mostly caused by thunder,but it also has other reasons. Power system cause: starting of heavy machine and short circuit fault. Unpredictable accident:traffic accident,construc...
read more
-
May 20,2020
STATCOM STATCOM (Static Synchronous Compensator)continuously provides variable reactive power in response to voltage variations, supporting the stability of the grid. STATCOM operates according to voltage source converter (VSC) principles, combining unique PWM (pulse width modulation) with millisecond switching. STATCOM functions with a very limited need for harmonic filters, contributing to a sma...
read more
-
Nov 30,2020
Relations between Reactive power,power factor and penalty Power Factor penalty is spelled out in the contract between the Power Company and Industrial or Commercial customer with large three phase loads. If the contract calls for 85% Power Factor, once the customer’s power factor falls below 85%, the Power Company bills the Customer according to the agreed penalty rates. Industrial loads are mostl...
read more
-
Jan 05,2021
Power factor correction capacitor banks and harmonic filters. Power factor correction capacitors and harmonic filters are an essential part of modern electric power systems. Power factor correction capacitors are the simplest and most economical means of increasing the capacity of any power system, minimizing energy losses and correcting load power factor. In addition, power factor penalties can b...
read more
-
Mar 04,2021
ZDDQ Active Harmonic Filter Active Harmonic Filter is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave, reactive power, and three-phase load unbalance. ZD-AHF-4 active harmonic filter is connected in parallel in 380V~456V power grid, to detect the harmonic wave in power grid in real time, generate the reverse-phase compensation current through the co...
read more
-
Mar 19,2021
Problems of Line Side Harmonics The two main line side harmonic concerns are the problems caused in the facility where they are being generated and the degree of harmonic infection passed to neighboring facilities. The degree of impact for either area depends on the number, size and frequency of use of all linear and non-linear loads . Mainly introduce harmoncs within a facility here. Within a fac...
read more
-
Mar 26,2021
Congratulations to the company for mentioning the new car Anhui Zhongdian Electric Co., Ltd., founded in 1988, is affiliated to the Design and Research Institute of the Ministry of Machinery Industry. It is a high-tech professional engaged in the R&D, production, sales and service of power quality equipment technology companies. The company passed the ISO9000 quality system certification in 20...
read more
-
Jun 24,2021
As an inexpensive source of reactive power, capacitor banks bring many benefits to a facility. They are widely deployed to avoid penalties on utility bills, lower distribution losses, increase transformer/Genset capacity, maintain nominal voltage, and to reduce energy losses resulting in decreased carbon emissions. When coupled with reactors, capacitor banks can filter harmonics generated by...
read more
-
Oct 17,2022
Warmly celebrate the 20th National Congress of the Communist Party of China held on October 16th The great changes of the decade in the new era have milestone significance in the history of the party, the history of new China, the history of reform and opening up, the history of socialist development, and the history of the development of the Chinese nation.
read more
-
Mar 15,2023
What is the Benefits of Capacitor banks? 1. Improved Power Quality: Capacitor banks are used to improve the power quality of an electrical system by reducing voltage fluctuations, harmonic distortion, and reactive power losses. 2. Increased Efficiency: Capacitor banks can be used to increase the efficiency of an electrical system by improving the power factor and reducing the amount of current req...
read more
-
Mar 20,2023
ELECTRONIC Power Compensation With electronic compensation it is possible to compensate inductive, capacitive and harmonic reactive power. In addition, it is possible to eliminate imbalances in the flows phase. This creates extra power space, limits energy losses and prevents fines and claims. Static Var Generator Active PFC Static Var Generator(SVG) compensates reactive power caused by inductive ...
read more