Jan 16,2020
There are a couple of principles to achieve reactive power compensation. The simplest solution is without any doubts a combination of switched passive elements, i.e. switched capacitors and inductors. Figure 1 shows qualitatively the reactive current versus connected voltage of such a solution. The reactive current depends linearly on the grid voltage and as a consequence the reactive power change...
read more
-
Sep 07,2021
Formulas of Related Harmonics The following calculator computes the total harmonic current distortion (THDc or THDi), Peak Current, RMS Current, and Crest Factor based on individual harmonic current distortion values between the 1st and the 50th harmonic. Input the fundamental current and individual harmonic currents to compute THDc(THDi) also to view a waveform plot based on the input values. The...
read more
-
Nov 22,2021
Reliable power distribution is needed to guarantee patient health and save lives in hospital. Continuity and reliability of power supply are extremely important in hospital.UPS,Generator,Medical devices include high volume of harmonics current, and can impact the distribution system in hospital. ZDDQ Active Harmonics Filter Based on the broad knowledge and experience in terms of solutions and appl...
read more
-
Apr 12,2024
Zero sequence current, known as residual current or triplen harmonic current, is a phenomenon that occurs in electrical systems due to the presence of unbalanced loads or nonlinear loads. The primary reason for the presence of zero current is unbalanced loads. In a three-phase power system, the loads are ideally balanced, meaning that the three phases draw equal currents. However, in practical sce...
read more
-
May 13,2024
The improvement of power quality is mainly through power quality equipment and current signal and other parameters in the current transformer detection system, so as to correctly control the power quality problem in real time and improve the environment of the distribution system. For capacitor bank, we usually only use a CT mounted on the power side for sampling. For SVG / APF, a...
read more
-
May 30,2024
1. What are the 3rd, 5th, and 7th harmonics? In a normal power system, electrical equipment with linear impedance change characteristics will not affect the power supply with a frequency of 50Hz and a standard sinusoidal waveform when it is working. However, with the development of power electronics technology, there are more and more electrical equipment with nonlinear impedance characteristics (...
read more
-
Jul 22,2024
Statcom, Current sampling and voltage sampling Current and Voltage Sampling in STATCOM Static Synchronous Compensator (STATCOM) is a device used for dynamic reactive power compensation and voltage stabilization in power systems. Accurate current and voltage sampling are crucial for the proper functioning of STATCOM, ensuring it provides the necessary reactive power compensation and voltage regulat...
read more
-
Aug 27,2024
Harmonic voltage and harmonic current are common phenomena in power systems, and they have a great impact on power equipment and power grid operation. Harmonics refer to voltage or current components whose frequencies are integer multiples of the fundamental frequency. In power systems, the fundamental frequency is generally 50Hz or 60Hz, so the harmonic frequency is an integer multiple of 50Hz or...
read more