33kv statcom

Passive harmonic filter

Shut Passive harmonic filters are widely used to limit harmonic propagation, to improve power quality, to reduce harmonic distortion, and to provide reactive power compensation. These are designed for high‐current and high‐voltage applications. Many such filters are in operation for HVDC transmission systems, large industrial drives, static VAR compensators, and so on.

  • Brand:

    ZDDQ
  • item no.:

    ZD-GWJ-M/6-A
  • Payment:

    LC,TT
  • price range:

    1000 - 30000/$1
  • product origin:

    China
  • Color:

    RAL7032
  • shipping port:

    Shanghai
  • Lead Time:

    15days
  • Product Detail

PASSIVE HARMONICS FILTER

It is the most common method for the cancellation of harmonic current in the distribution system. Passive harmonic filter are basically designed on principle of either single tuned or band pass filter technology. As the name suggests shunt type filter are connected in system parallel with load. Passive filter offer a very low impedance in the network at the tuned frequency to divert all the related current & at given tuned frequency. Because of passive filter always have tendency of offering some reactive power in the circuit so the design of passive shunt filter take place for the two purpose one is the filtering purpose & another one is to provide reactive compensation purpose of correcting power factor in the circuit at desired level. The advantage with the passive shunt type filter is that it only carry fraction of current so the whole system AC power losses are reduced compare to series type filter. The given figure shows the schematic diagram of 6 pulse converter system connected with shunt passive type filter which are simply employed ever connection in distribution system have R-L load in system.


CHARACTERISTICS OF PASSIVE FILTER WITH FIXED ELEMENTS

Passive filters were preferred in the earlier days for harmonic compensation because they are simple in structure and easy to install Different topologies of passive filters were emerged during stages of research. They are generally classified into series and shunt passive filters. Series passive filters use high series impedance to block harmonics, and shunt filters divert harmonics by means of a low impedance shunt path. The series filters must be designed to carry full load current, whereas shunt filters carry only a fraction of the current that a series filter carries. Also shunt filters, if properly designed, supply reactive power to the load at the fundamental frequency. Hence the most practical approach is to use shunt passive filters. The shunt passive filter is made up of passive elements resistance, inductance and capacitance. When the inductive and capacitive reactance of the passive filter become equal at a particular harmonic frequency, shunt passive filter acts as low impedance path for that harmonic component.


SPECIFICATION

Models  ZD-GWJ-PF-
Voltage 3-35 kV
Power 100Kvar~1200Kvar
Fundamental frequency 50 or 60 Hz
Tuning frequency Optional
Installation Indoor or outdoor
Capacitors Film Capacitor banks
Reactor Air or iron core

passive power filter
passive shunt filter
            MV Passive filter                                                                               Capacitors and Reactors


ADVANTAGES OF PASSIVE FILTERS

  1. Higher power factor, improved voltage stability and lower network losses.
  2. Filtering of harmonics in the system to acceptable levels.
  3. Lowering of resonance problems and amplification of electrical disturbances
  4. Less Cost.
  5. Gain and Frequency adjustment flexibility
  6. No Loading Problem
  7. Non-floating Input and output
A “clean” network creates much less strain on equipment and lengthens its life span. This results in a lower maintenance cost and the cost for replacing worn-out equipment. ZDDQ passive harmonic filters are the ideal solution to render medium/high-voltage networks more efficient and trouble-free. 


 APPLICATIONS

Nonlinear loads such as saturated coils and transformers are the main cause of producing harmonics in power system. Power electronic creates most of the due to its non liner characteristics pollution issues. Most of the pollution issues are created due to the nonlinear characteristics and fast switching of Power electronics.

Classically, shunt passive harmonic filters, mainly consist of tuned LC filters and or high passive filters are used to reduce the harmonics and power capacitors are used to improve the power factor. But they have the limitations of fixed compensation, large size and can also exile resonance conditions. In this work both shunt passive filter is used for power quality improvement. Transformers, motors, cables, interrupters and capacitors are the some equipment which is affected by harmonics converters mainly produces notches and they basically affect the electronic control devices.

There are two routes to the reduction of power quality problems. The first way is known as load conditioning, which assures that the equipment is made less sensitive and effective to power disturbances. The second technique is, to install line-conditioning systems that counteract or suppress the power system disturbances .In distribution systems passive filters have been used to limit of harmonic currents.









Send a Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
related products
Passive filter

Shut passive power filter

Shut Passive power filters are widely used to limit harmonic propagation, to improve power quality, to reduce harmonic distortion, and to provide reactive power compensation. These are designed for high‐current and high‐voltage applications. Many such filters are in operation for HVDC transmission systems, large industrial drives, static VAR compensators, and so on.
FC filter capacitor banks

Medium Voltage filter capacitor (FC) banks

Medium Voltage filter capacitor (FC) banks  are widely used to limit harmonic propagation, to improve power quality, to reduce harmonic distortion, and to provide reactive power compensation. These are designed for high‐current and high‐voltage applications. Many such filters are in operation for HVDC transmission systems, large industrial drives, static VAR compensators, and so on.
reactive power compensator SVG statcom

High voltage reactive power compensator SVG STATCOM

High voltage reactive power compensator SVG STATCOM is a voltage regulating device. It is based on a power electronics voltage source converter (VSC) and can act as either a source or sink of reactive AC power. It is a member of the flexible AC transmission systems (FACTS) family which detects and instantly compensates for voltage fluctuations or flicker, as well as controls power factor.
Power capacitor banks along with APFC panel

LT Power capacitor banks along with APFC panel

ZDDQ low voltage automatic capacitor banks based on Thyristor(TSC) improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring.
active harmonic filter

50A Smart Active Harmonic Filter Module

Active harmonic filter(AHF) is connected in parallel with non-linear loads, and uses one set of CT to detect the load current. It calculates each order harmonic current by FFT algorithms in its DSP microchips, and then generates a compensating current with the same amplitude but opposite phase angles to the detected harmonic current, which cancels out the original load harmonics.Not only eliminates harmonic current from the load side, but it also mitigates harmonic voltage caused by harmonic currents. The AHF system can also improve power factor (PF) and correct load imbalances in the power system.
25A active harmonic filter

25A Active Power Filter

Active Power filter(APF) is connected in parallel with non-linear loads, and uses one set of CT to detect the load current. It calculates each order harmonic current by FFT algorithms in its DSP microchips, and then generates a compensating current with the same amplitude but opposite phase angles to the detected harmonic current, which cancels out the original load harmonics.Not only eliminates harmonic current from the load side, but it also mitigates harmonic voltage caused by harmonic currents. The AHF system can also improve power factor (PF) and correct load imbalances in the power system.
BEss Energy storage system

2.4M/2.75M/3.15M/3.45M Energy Storage System

The transition to renewable energy makes it harder than ever to provide energy reliably where and when it is required, considering the enormous quantity of energy consumed in today’s modern world and government goals to reduce carbon emissions. As a result, there is a growing need for energy storage devices. The power conversion system (PCS) is a crucial element of any effective energy storage system (ESS). Between the DC batteries and the electrical grid, the PCS serves as an interface.
mobile statcom

Outdoor mobile STATCOM

ZDDQ Outdoor Mobile STATCOM is a modular system from 6kv to 35kv, supplies reactive power to distribution grids with high regulating dynamics, and carries out regulating tasks such as voltage regulation or influencing the flow of reactive power.
Send a Message
welcome to zddq
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact