27.5KV automatic power factor correction/reactive power compensation systems are used everywhere that motors are still directly operated without power electronics, or other consumers with a low inductive cosφ place strain on the grid with reactive power in addition to their active-power requirements. Local supply of this reactive power by means of compensation systems relieves the burden on the supply grid and reduces losses.
Brand:
ZDDQitem no.:
ZD-GWJ-27.5/6-APayment:
LC,TTproduct origin:
ChinaColor:
RAL7032shipping port:
ShanghaiLead Time:
15daysOverview of 27.5Kv APFC panel
27.5KV Active Power Factor Correction Panel based on Static Var Compensator aims to improve power factor and enhance power quality, utilising capacitors to offset usually inductive loads(motors). SVC APFC system increase the efficiency of power supply, delivering immediate cost savings on electricity.
ZD-GWJ Series 27.5KV Active Power Factor Correction Panel: can detect the reactive power needed by the system in real time,compare it with the set value, carry on the automatic intelligent capacitor-switching on/off, make the reactive power of the system achieve dynamic balance, in order to improve the power factor of the system, stabilize the system voltage.
Following are effect before and after power factor correction,
27.5kv Automatic Power factor correction panel
ZD-GWJ-27.5/6-
Name
Model
Rated Voltage
27.5Kv
Connection Type
Three-phase 3 wire
Rated Frequency
50/60HZ
Step Capacity
1MVAr
Rated Capacity
1~100MVAr
Power Factor
0.9
Switch
Vacuum Contactors
Capacitance Tolerance
-5%, +10%
Reactance ratio
6% 12% or customerized
Switching
Automatic switching Capacitors
Storage temperature
-40~85 °C
Working temperature
-25~55 °C
Humidity
≤95%,non-condensate
Dimension (mm)
Open Rack Type
Installation
Indoor, free standing
Altitude
<1500m without de-rating
Certification
ISO9001,CCC, Type Test Report
Features
■Fast return on investment through lower power costs
Power factor correction reduces the reactive power in a system. Power consumption and power costs drop in proportion.
■Effective use of installation
An improved power factor means that an electrical installation operates more economical (higher effective power for the same apparent power).
■Improved voltage quality
■Reduced voltage drops
■Optimum cable design
Cable cross-sections can be reduced with improvement of power factor (less current). In existing installations for instance, extra or higher power can be transmitted.
■Reduced transmission losses
The transmission and switching devices carry less current, i.e. only the effective power, meaning that the ohmic losses in the leads are reduced.
Application
ZDDQ automatic capacitor banks are widely used for fluctuating loads such as motors, variable frequency drives, melting furnace from Steel Rolling mills,Chemical industry,Cement plant, Suger plant, Textile, Hospitals, Hotels, Building segment,Automobile industry,Oil and gas industry,public grid etc.
Scan to WhatsApp: