Mar 25,2024
Static Synchronous Compensator (STATCOM) is a device used in power systems to control voltage and reactive power. In the context of rail transit, STATCOM can serve several purposes: Voltage Regulation: STATCOM can regulate the voltage levels in the rail transit system, ensuring that they remain within acceptable limits. It can compensate for voltage drops or fluctuations caused by various factors ...
read more
-
Apr 12,2024
Zero sequence current, known as residual current or triplen harmonic current, is a phenomenon that occurs in electrical systems due to the presence of unbalanced loads or nonlinear loads. The primary reason for the presence of zero current is unbalanced loads. In a three-phase power system, the loads are ideally balanced, meaning that the three phases draw equal currents. However, in practical sce...
read more
-
Apr 25,2024
To connect a Static Synchronous Compensator (STATCOM) to a high voltage system, you need to follow a series of steps and ensure compliance with safety regulations: System Design: Determine the appropriate rating and configuration of the STATCOM based on the requirements of the high voltage system. Consider factors such as voltage level, reactive power compensation, and system stability. Equipment ...
read more
-
May 05,2024
To realize the connection of a Static Synchronous Compensator (STATCOM) to a high voltage system and address negative sequence compensation, you need to follow certain steps: Determine the system requirements: Assess the voltage levels, power ratings, and control requirements of your high voltage system. Understanding the specific needs will help you design and configure the STATCOM accordingly. C...
read more
-
May 13,2024
The improvement of power quality is mainly through power quality equipment and current signal and other parameters in the current transformer detection system, so as to correctly control the power quality problem in real time and improve the environment of the distribution system. For capacitor bank, we usually only use a CT mounted on the power side for sampling. For SVG / APF, a...
read more
-
May 30,2024
1. What are the 3rd, 5th, and 7th harmonics? In a normal power system, electrical equipment with linear impedance change characteristics will not affect the power supply with a frequency of 50Hz and a standard sinusoidal waveform when it is working. However, with the development of power electronics technology, there are more and more electrical equipment with nonlinear impedance characteristics (...
read more
-
Jun 03,2024
33kV Capacitor Banks Static Reactive Power Compensation: Capacitor banks provide fixed reactive power compensation. Simple Technology: Consists of capacitors connected in series or parallel to provide reactive power. Advantages: Cost-Effective: Typically less expensive than STATCOM, making them a cost-effective solution for reactive power compensation. Simplicity: Easier to install and maintain du...
read more
-
Jul 01,2024
STATCOM (Static Synchronous Compensator) is a power electronic device used power systems for voltage control and power factor correction. While Statcom are not directly related to coal mining operations, they can play a role in providing stable and reliable electrical power for mining operations, including coal mines. Coal mines typically require a significant amount of electrical power for variou...
read more
-
Jul 16,2024
STATCOM and Voltage Flicker Mitigation What is votlage flicker? Voltage flicker refers to the rapid and repeated fluctuations in the voltage level of a power supply, which can cause noticeable changes in the intensity of lighting and can affect the performance of other electrical equipment. These fluctuations can be annoying and may lead to operational issues in sensitive equipment Causes of Volta...
read more
-
Jul 22,2024
Statcom, Current sampling and voltage sampling Current and Voltage Sampling in STATCOM Static Synchronous Compensator (STATCOM) is a device used for dynamic reactive power compensation and voltage stabilization in power systems. Accurate current and voltage sampling are crucial for the proper functioning of STATCOM, ensuring it provides the necessary reactive power compensation and voltage regulat...
read more
-
Aug 19,2024
Response time of reactive power compensation product The response time of a reactive power compensation product refers to the time it takes for the device to detect a change in the reactive power demand and adjust its output accordingly to maintain the desired power factor or voltage level. This is a crucial performance metric for systems that require rapid compensation, such as those with dynamic...
read more
-
Aug 27,2024
Harmonic voltage and harmonic current are common phenomena in power systems, and they have a great impact on power equipment and power grid operation. Harmonics refer to voltage or current components whose frequencies are integer multiples of the fundamental frequency. In power systems, the fundamental frequency is generally 50Hz or 60Hz, so the harmonic frequency is an integer multiple of 50Hz or...
read more
-
Sep 10,2024
What is the relation of Static var generator and Carbon reduction? Static Var Generator (SVG) plays a significant role in reducing carbon emissions by improving the efficiency of electrical systems. Here's how SVGs contribute to carbon reduction: 1. Improved Power Factor SVG help improve the power factor of an electrical system by providing reactive power compensation. A low power factor leads to ...
read more
-
Sep 24,2024
What is the reason of resonance in power networks? Resonance in power networks occurs when the inductive and capacitive elements of the system interact in a way that amplifies specific frequencies, leading to excessive voltage or current oscillations. Here are the primary reasons for resonance in power networks: 1. Impedance Matching Resonant Frequency: Every electrical circuit has a natural reson...