Nov 21,2019
ZDDQ power quality correction products are part of the solution. Most utilities charge for peak electrical demand on each month’s electrical bill. The demand charge is to allow the utilities to recoup part of their capital investment in the distribution network they operate. Each customer pays a demand charge for its peak operating load. Often inherent in the structure of these demand charges is a...
read more
-
Nov 23,2019
Fundamental (component) The component of order 1 of the Fourier series of a periodic quantity. (IEV 161-02-17) Harmonic The component of the Fourier-series decomposition of a volt- age or current periodic wave. (IEV 161-02-18 modified) Harmonic order (h) The ratio of the frequency of a harmonic (fh) to the fundamen- tal (rated) network frequency (f1). (IEV 161-02-19 modified) Odd harmonics Harmoni...
read more
-
Nov 29,2019
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Dec 05,2019
Typical non-linear loads We will be focusing on the six pulse rectifier bridge. The 3 phase rectifier has a key role to play because a significant portion of the electrical energy is drawn from loads with this type of front-end circuit. One typical application that can be mentioned is the variable speed motor drive, which has been used for years with high growth rates in almost every industrial se...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 3: Allowance for operating conditions and harmonics Capacitor banks should be selected depending on the working conditions expected during their lifetime. Allowing for operating conditions The operating conditions have a great influence on the life expectancy of capacitors. The following parameters should be taken into a...
read more
-
Jan 07,2020
Part 1:Principle of reactive energy management All AC electrical networks consume two types of power: active power (kW) and reactive power (kVAr): The active power P (in kW) is the real power transmitted to loads such as motors,lamps, heaters, computers, etc. The electrical active power is transformed into mechanical power, heat or light. The reactive power Q (in kVAr) is used only to power the ma...
read more
-
Jan 19,2020
A changing electrical network brings new power quality issues. Today the way we generate, use, and control our energy is changing. New and renewable generation and distribution technology is becoming common, and combined with more dynamic and complex load profiles, there are more challenges faced by the network and energy users to provide high power quality. A new way to improve your power quality...
read more
-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 10,2020
WHAT IS HARMONIC FILTERING? To understand the purpose of harmonic filtering, it helps to understand what harmonics are. The voltage of a standard 50Hz Alternating Current(AC) power supply swings between positive and negative 50 times a second, following a neat sine-wave. Linear AC electrical loads such as heaters or incandescent lights draw a current that follows this same sine-wave. The graph abo...
read more
-
Feb 18,2020
How much can be saved? Ultimately the level of energy saving achieved will be dictated by a combination of the incoming supply voltage level and the types of electrical equipment in use. The higher the supply voltage, the greater the potential to make energy savings. However different types of electrical equipment deliver different levels of energy saving for the same reduction in voltage. Voltage...
read more
-
Mar 23,2020
Overview of Active Power Filter APF-1000 APF-1000 Active power filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensation, and the proportion of compensation capacity by harmonic, reactive power, and three-phase unbalance can also be set, comprehensively solving the problem of ...
read more
-
Dec 09,2020
The static var generator (SVG) with appropriate control method is a good solution to solve the problem of reactive power impact and harmonic pollution which is generated by the nonlinear load. A control strategy using active current separation and the current indirect control is used for SVG. The active current separation is a method for detecting the harmonic and reactive current, and then the su...
read more
-
Dec 22,2020
SVG: Static Var Generator ANHUI ZHONGDIAN ELECTRIC CO., LTD. static var generator is a static electrical device/equipment/system that draws controlled capacitive or inductive current from the electrical power system and thereby generates or absorbs reactive power. Permanently connected and switchable reactor and capacitor banks have been always used in AC power systems to ensure desirable voltages...
read more
-
Dec 26,2020
Power factor is the percentage of consumed power(KW) versus supplied power(KVA). This is important because a low power factor can waste energy, result in inefficient use of electrical power, and often result in higher energy bills. Power Factor Correction will improve the energy efficiency of any electrical system, but a reduction in your power bill is only available where a power company charges ...
read more
-
Dec 29,2020
The rising power consumption for the power quality equipment is the key driving factor for the market growth ZDDQ found according to the report: The global power quality equipment market size is projected to reach nearly USD 33.7 billion by 2028. Additionally, the market is forecasted to grow a CAGR of above 6.5% over the forecast period of 2020-2028. The key motivating force for the power efficie...
read more
-
Jan 16,2021
Status analysis According to marketing research by ZDDQ(ANHUI ZHONGDIAN ELECTRC CO., LTD.). To reduce energy consumption and increase energy efficiency, many facility management executives are looking to renewable energy sources, such as solar or wind, to offset reliance on traditional electric power. Despite the growing prevalence of these solutions, there are drawbacks that can make alternative ...
read more
-
Jan 27,2021
Overview ZDDQ Active Power Filter have exported to many countries all over the world. These filters are widely used in a number of industries such as oil & gas, manufacturing, water/wastewater, metal and mining, and paper and pulp. A harmonic filter is used to mitigate harmonics created by non-linear loads in electrical equipment. Classification Ⅰ. Product Insights Based on product type, ...
read more
-
Feb 02,2021
Harmonics in power system. In an electric power system, a harmonic is a voltage or current at a multiple of the fundamental frequency of the system, produced by the action of non-linear loads such as rectifiers, discharge lighting, or saturated magnetic devices. Harmonic frequencies in the power grid are a frequent cause of power quality problems. Harmonics in power systems result in increased hea...