Nov 21,2019
ZDDQ power quality correction products are part of the solution. Most utilities charge for peak electrical demand on each month’s electrical bill. The demand charge is to allow the utilities to recoup part of their capital investment in the distribution network they operate. Each customer pays a demand charge for its peak operating load. Often inherent in the structure of these demand charges is a...
read more
-
Nov 22,2019
Based on the power of a receiver in kW, this table can be used to calculate the power of the capacitors to change from an initial power factor to a required power factor. It also gives the equivalence between cosΦ tanΦ,
read more
-
Nov 22,2019
In an L.V/M.V/H.V electrical installation, capacitor banks (or Static var generator/Active harmonic filter)can be installed at 3 different levels. 1.Global installation Advantages: - No reactive energy bill. - Represents the most economical solution since all the power is concentrated at one point and the expansion coefficient makes it possible to optimize banks - Relieves the transformer. Remark:...
read more
-
Nov 23,2019
Rated insulation level The combination of voltage values that characterizes the insulation of the equipment with regard to its capability to withstand dielectric stresses. These values are selected based on the rated voltage of the bank/system. Standard insulation values are given for altitudes <1000 m above sea level. For higher altitudes, a correction factor must be used. Lightning impulse te...
read more
-
Nov 23,2019
Capacitor element Device consisting essentially of two electrodes separated by a dielectric (IEV 436-01-03). Capacitor unit Assembly of one or more capacitor elements in the same container with external terminals (IEV 436-01-04). Capacitor bank Multiple capacitor units connected so as to act together (IEV 436-01-06). Capacitor The word “capacitor” is used when it is not necessary to put particular...
read more
-
Nov 23,2019
Fundamental (component) The component of order 1 of the Fourier series of a periodic quantity. (IEV 161-02-17) Harmonic The component of the Fourier-series decomposition of a volt- age or current periodic wave. (IEV 161-02-18 modified) Harmonic order (h) The ratio of the frequency of a harmonic (fh) to the fundamen- tal (rated) network frequency (f1). (IEV 161-02-19 modified) Odd harmonics Harmoni...
read more
-
Nov 28,2019
Standard Features Enclosure ZDDQ Capacitor banks,free standing, compartmentalized, all welded, galvanneal steel construction with 3 point pad-lockable latching handles and stainless steel hinges. The enclosure is painted with a corrosion resistant ANSI gray-61 epoxy paint. NEMA 3R construction is standard; NEMA 12 and 4X are available as an option. Base of enclosure as well as capacitor supports a...
read more
-
Nov 29,2019
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Dec 05,2019
Typical non-linear loads We will be focusing on the six pulse rectifier bridge. The 3 phase rectifier has a key role to play because a significant portion of the electrical energy is drawn from loads with this type of front-end circuit. One typical application that can be mentioned is the variable speed motor drive, which has been used for years with high growth rates in almost every industrial se...
read more
-
Dec 05,2019
What's the Definition of Power Factor? Power Factor Definition: Power factor(PF for short) is the ratio between KW and KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively the current is being converted into useful work output and more particularly is a good indicator of the effect of the load current on th...
read more
-
Dec 07,2019
Active Harmonic Filter Active Harmonic Filter has many potential applications where its use can offer plenty of benefits. Active Harmonic Filters have been proven to provide lowered disturbances, lower carbon dioxide emissions through improved energy efficiency, lower current consumption and increased production stability to name a few. Just as other technology has evolved, so have various product...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 3: Allowance for operating conditions and harmonics Capacitor banks should be selected depending on the working conditions expected during their lifetime. Allowing for operating conditions The operating conditions have a great influence on the life expectancy of capacitors. The following parameters should be taken into a...
read more
-
Dec 23,2019
The Graph below shows Harmonic Current Distortion in the form of THDi. This is hovering between 20 and 25%. Ideally, it should be less than 10% and preferably less than 8% THDi. The highest value of average total harmonic distortion (THDi%) across three phases was calculated from raw data. This value is 24.19%THDi and was recorded at time shown. At the same time, average line current (Amps) across...
read more
-
Dec 25,2019
We make a simple introduction about harmoincs in networks,welcome to communicate with us about harmonics and how to solve. General Introduction Harmonics are usually defined by two main characteristics: Their amplitude: value of the harmonic voltage or current. Their order: value of their frequency with respect to the fundamental frequency (50 Hz). Under such conditions, the frequency of a 5th ord...
read more
-
Jan 02,2020
The effects of harmonics on loads The following two types of effects appear in the main equipment: immediate or short-term effects and long-term effects. Immediate or short-term effects: Unwanted tripping of protection devices, Induced interference from LV current systems (remote control, telecommunications), Abnormal vibrations and noise, Damage due to capacitor thermal overload, Faulty operation...
read more
-
Feb 01,2020
To our clients, You may have had some good memories about the past one, but you never know what’s the new one is bringing for you. It's time to be hopeful, have new dreams and make some new resolutions for the new year in your life. It's time to connect with each other and make new year wishes. Its time to move on and embrace what’s new. New year means a lot of new dreams and new achievements. Peo...
read more
-
Feb 04,2020
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...