Nov 23,2019
Fundamental (component) The component of order 1 of the Fourier series of a periodic quantity. (IEV 161-02-17) Harmonic The component of the Fourier-series decomposition of a volt- age or current periodic wave. (IEV 161-02-18 modified) Harmonic order (h) The ratio of the frequency of a harmonic (fh) to the fundamen- tal (rated) network frequency (f1). (IEV 161-02-19 modified) Odd harmonics Harmoni...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 3: Allowance for operating conditions and harmonics Capacitor banks should be selected depending on the working conditions expected during their lifetime. Allowing for operating conditions The operating conditions have a great influence on the life expectancy of capacitors. The following parameters should be taken into a...
read more
-
Dec 23,2019
The Graph below shows Harmonic Current Distortion in the form of THDi. This is hovering between 20 and 25%. Ideally, it should be less than 10% and preferably less than 8% THDi. The highest value of average total harmonic distortion (THDi%) across three phases was calculated from raw data. This value is 24.19%THDi and was recorded at time shown. At the same time, average line current (Amps) across...
read more
-
Dec 25,2019
We make a simple introduction about harmoincs in networks,welcome to communicate with us about harmonics and how to solve. General Introduction Harmonics are usually defined by two main characteristics: Their amplitude: value of the harmonic voltage or current. Their order: value of their frequency with respect to the fundamental frequency (50 Hz). Under such conditions, the frequency of a 5th ord...
read more
-
Jan 02,2020
The effects of harmonics on loads The following two types of effects appear in the main equipment: immediate or short-term effects and long-term effects. Immediate or short-term effects: Unwanted tripping of protection devices, Induced interference from LV current systems (remote control, telecommunications), Abnormal vibrations and noise, Damage due to capacitor thermal overload, Faulty operation...
read more
-
Jan 27,2021
Overview ZDDQ Active Power Filter have exported to many countries all over the world. These filters are widely used in a number of industries such as oil & gas, manufacturing, water/wastewater, metal and mining, and paper and pulp. A harmonic filter is used to mitigate harmonics created by non-linear loads in electrical equipment. Classification Ⅰ. Product Insights Based on product type, ...
read more
-
Mar 19,2021
Problems of Line Side Harmonics The two main line side harmonic concerns are the problems caused in the facility where they are being generated and the degree of harmonic infection passed to neighboring facilities. The degree of impact for either area depends on the number, size and frequency of use of all linear and non-linear loads . Mainly introduce harmoncs within a facility here. Within a fac...
read more
-
May 18,2021
Harmonics and Active Power Filter In recent years, the use of non-linear load is increasing day by day. Non-linear loads such as traditional diode/ thyristor rectifiers with inductive load generate harmonic and reactive current, which leads to poor power factor, low energy efficiency, and harmful disturbance to other appliances. Also, in recent years, the large-scale use of the power electronic eq...
read more
-
Sep 07,2021
Formulas of Related Harmonics The following calculator computes the total harmonic current distortion (THDc or THDi), Peak Current, RMS Current, and Crest Factor based on individual harmonic current distortion values between the 1st and the 50th harmonic. Input the fundamental current and individual harmonic currents to compute THDc(THDi) also to view a waveform plot based on the input values. The...
read more
-
Oct 28,2021
ZDDQ-AHF Active Harmonic Filter ZDDQ Active Harmonic Filter(AHF) is used to improve Power Quality through autonomous detection and dynamic filtering of harmonic currents present in power grid. ZDDQ Active Harmonics Filter is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave, reactive power, and three-phase load unbalance. ZD AHF is connected in parall...
read more
-
Nov 05,2021
ZDDQ Active Harmonic Filter(APF/AHF for short) is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave(can filter 2nd to 50th harmonic interference completely), reactive power, and 3 phase load unbalance. Active Harmonic Filter is connected in parallel in power grid, to detect the harmonic wave in power grid in real time, generate the reverse-phase compe...
read more
-
Nov 22,2021
Reliable power distribution is needed to guarantee patient health and save lives in hospital. Continuity and reliability of power supply are extremely important in hospital.UPS,Generator,Medical devices include high volume of harmonics current, and can impact the distribution system in hospital. ZDDQ Active Harmonics Filter Based on the broad knowledge and experience in terms of solutions and appl...
read more
-
Mar 06,2023
ZDDQ Active Power Filters exported to Thailand. We have been cooperating with this customer for almost 3 years. The quality of our Active Power Filter is stable, the technical and market performance is excellent, the order demand of the customer is stable, and we have formed a relatively good reputation in the market. Thanks for Client's trust and support.Not more than 2 months, this new order is ...
read more
-
Feb 19,2024
What is harmonics issues in AC and DC grid? In AC and DC grids, harmonics refer to the presence of frequency components that are integer multiples of the fundamental frequency. Harmonics can be problematic because they can cause various issues such as: Voltage and Current Distortion: Harmonics in the grid can distort the shape of the voltage and current waveforms, resulting in distorted sine waves...
read more