Nov 23,2019
Capacitor element Device consisting essentially of two electrodes separated by a dielectric (IEV 436-01-03). Capacitor unit Assembly of one or more capacitor elements in the same container with external terminals (IEV 436-01-04). Capacitor bank Multiple capacitor units connected so as to act together (IEV 436-01-06). Capacitor The word “capacitor” is used when it is not necessary to put particular...
read more
-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 02,2021
Harmonics in power system. In an electric power system, a harmonic is a voltage or current at a multiple of the fundamental frequency of the system, produced by the action of non-linear loads such as rectifiers, discharge lighting, or saturated magnetic devices. Harmonic frequencies in the power grid are a frequent cause of power quality problems. Harmonics in power systems result in increased hea...
read more
-
Apr 12,2021
Power Quality Solutions and Energy Savings One of the most significant changes in the Power Quality industry in the past five years is the method of selling Power Quality solutions. Originally, Power Quality solutions were sold as an insurance policy to avoid potential damage from power disturbances such as transients,voltage sags, interruptions or harmonics. Today, many Power Qu...
read more
-
Oct 28,2021
ZDDQ-AHF Active Harmonic Filter ZDDQ Active Harmonic Filter(AHF) is used to improve Power Quality through autonomous detection and dynamic filtering of harmonic currents present in power grid. ZDDQ Active Harmonics Filter is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave, reactive power, and three-phase load unbalance. ZD AHF is connected in parall...
read more
-
Feb 18,2022
Thanks for Pakistan Client's trust and support. 300A Active Harmonic Filter Panels.
read more
-
Jul 29,2024
The preventive measures for the capacity attenuation of power capacitors are crucial in the application of power capacitor banks. Here are some of the main preventive measures: Control operating conditions: Temperature control: Ensure that the capacitor operates within the temperature range recommended by the manufacturer. Excessive temperature will accelerate the aging of the internal materials o...
read more