-
Dec 09,2020
The static var generator (SVG) with appropriate control method is a good solution to solve the problem of reactive power impact and harmonic pollution which is generated by the nonlinear load. A control strategy using active current separation and the current indirect control is used for SVG. The active current separation is a method for detecting the harmonic and reactive current, and then the su...
read more
-
Jan 05,2021
Research A recent ZDDQ survey shows that the global static VAR generator market is projected to grow remarkably owing to the persistent demand for stable power supply from the consumers. Knowing from Fortune Business Insights, in an upcoming report, titled, “Static VAR Generator“ Market Size, Share & Industry Analysis, By Type (Thyristor Based, MCR Based), By End-User (Electric Utility, Renewa...
read more
-
Jan 16,2021
Status analysis According to marketing research by ZDDQ(ANHUI ZHONGDIAN ELECTRC CO., LTD.). To reduce energy consumption and increase energy efficiency, many facility management executives are looking to renewable energy sources, such as solar or wind, to offset reliance on traditional electric power. Despite the growing prevalence of these solutions, there are drawbacks that can make alternative ...
read more
-
Feb 03,2021
HV/MV Power factor correction is directly related to the different aspects that assist the technical management of transport and distribution networks. These are: Power quality This involves the increase in the levels of voltage in substation busbars and line ends. Optimisation of the installation's cost of operation In other words, the decrease of the reactive energy and, therefore, the reduction...
read more
-
Mar 08,2021
High Voltage Power Capacitors Fields of Application INDIVIDUAL POWER FACTOR CORRECTION The power factor correction capacitor is connected directly to the terminals of the consumer and will be switched together with it. Advantages of individual capacitors at the load: • Complete control; capacitors cannot cause problems on the line during light load conditions • No need for separate switching...
read more
-
Mar 20,2021
A capacitor bank is a grouping of several identical capacitors interconnected in parallel or in series with one another. These groups of capacitors are typically used to correct or counteract undesirable characteristics, such as power factor lag or phase shifts inherent in alternating current (AC) electrical power supplies. FEATURES: Power factor correction by multi step design Standard & detu...
read more
-
Jul 22,2021
An example of how to calculate the capacity of reactive power (kVAr)? An Motor is supplying a load of 700 kW at a P.F (Power factor) of 0.65. What size of Capacitor in kVAr is required to raise the P.F (Power Factor) to unity (1)? And how many more kW can the motor supply for the same kVA loading when P.F improved. Supplying kW = 700 kW Original P.F = Cosθ1 = 0.65 Final P.F = Cosθ2 = 1 θ1 = C...
read more
-
Jan 20,2022
Static Synchronous compensator (STATCOM) is a fast-acting device capable of providing or absorbing reactive current and thereby regulating the voltage at the point of connection to a power grid. It is categorised under Flexible AC transmission system (FACTS) devices. The technology is based on VSCs with semi-conductor valves in a modular two-level configuration. ZDDQ Statcom have installed in many...
read more
-
Jun 30,2022
The benefits of power factor correction 1.Savings on the electricity bill Power factor correction eliminates penalties on reactive energy, decreases demand on kVA, and reduces power losses generated in the transformers and conductors of the installation. 2.Increased available power Fitting PFC equipment on the low voltage side increases the power available at the secondary of a MV/LV transformer. ...
read more
-
Aug 09,2022
ZDDQ-SVG Static Var Generator is an electronic reactive power compensation system, for both capacitive and inductive power. It has the same operating principle as an active filter; the SVG injects a current in the opposite direction to counteract the installation's non-useful power (inductive and capacitive), thus ensuring that the target cosϕ is achieved. ZDDQ SVG instantly compensates and adjust...
read more
-
Sep 08,2022
ZDDQ Low Voltage Capacitor Banks provide a cost-effective, user friendly, reliable solution for power factor correction. They are a more efficient alternative to individual motor capacitors, especially in large industrial facilities. ZDDQ Power Factor Correction Panels are designed to provide power factor correction with a single installation on the main plant bus and are ideal for applications wh...
read more
-
Dec 05,2022
Reactive Power in Inductive Loads Inductive loads such as chokes, motors, inductive heating equipment, generators, transformers, and arc welding equipment produce an electrical lag that is commonly referred to as inductance. This inductance causes a phase difference between current and voltage. As a result of phase shift due to inductance, there are times when current and voltage have different si...
read more
-
Mar 06,2023
ZDDQ Active Power Filters exported to Thailand. We have been cooperating with this customer for almost 3 years. The quality of our Active Power Filter is stable, the technical and market performance is excellent, the order demand of the customer is stable, and we have formed a relatively good reputation in the market. Thanks for Client's trust and support.Not more than 2 months, this new order is ...
read more
-
Oct 14,2023
ZDDQ-LV APFC Low voltage reactive power compensation refers to the process of correcting or improving the reactive power in a low voltage electrical system. Reactive power is the power associated with reactive components, such as inductive or capacitive loads, in an alternating current (AC) circuit. In an AC power system, both real power (measured in watts) and reactive power (measured in vo...
read more
-
Dec 02,2023
ZD-GWJ Medium Voltage(3kV~24kV) group automatic reactive power compensation device automatically switches capacitor banks according to the voltage and reactive power of the power supply bus, and performs reactive power compensation by tracking load changes, thereby providing power factor, improving power supply quality, and reducing power consumption. It is often installed in front of the control ...
read more
-
Jan 29,2024
To build a capacitor bank panel, you will need to follow these general steps: Determine the capacitor bank size: Calculate the required capacitance based on the power factor correction needs of your system. Consider factors such as the target power factor, load characteristics, and voltage levels. Select capacitors: Choose high-quality capacitors that are suitable for the desired voltage and curre...
read more
-
Feb 26,2024
A Static Synchronous Compensator (STATCOM) is a power electronic device used for voltage control and reactive power compensation in electrical power systems. It is typically connected to the grid and is capable of injecting or absorbing reactive power to regulate the system voltage. The control of voltage by a STATCOM is primarily achieved by manipulating its reactive power output. Here's a basic ...
read more
-
Mar 20,2024
Urban rail transit systems mainly include: subway systems, light rail systems, monorail systems, trams, maglev systems, automatic guide rail systems, and urban rapid rail systems. According to the different nature of electricity consumption, the power supply system of the subway system is mainly divided into two, one is the traction power supply system and the other is the power lighting power sup...
read more