-
Sep 19,2019
Anhui Zhongdian(ZDDQ) Electric Co., Ltd. established in 2001. ZDDQ Technology Park locates in Bengbu City of Anhui Provice. We're a professional and leading manufacture, focus on advanced power quality solutions and power factor correction. APF,SVG,APFC are our main products. ZDDQ have a leading independent R&D team and quality supervision system, and maintain long-term cooperative relations w...
read more
-
Nov 21,2019
ZDDQ power quality correction products are part of the solution. Most utilities charge for peak electrical demand on each month’s electrical bill. The demand charge is to allow the utilities to recoup part of their capital investment in the distribution network they operate. Each customer pays a demand charge for its peak operating load. Often inherent in the structure of these demand charges is a...
read more
-
Nov 22,2019
Based on the power of a receiver in kW, this table can be used to calculate the power of the capacitors to change from an initial power factor to a required power factor. It also gives the equivalence between cosΦ tanΦ,
read more
-
Nov 22,2019
In an L.V/M.V/H.V electrical installation, capacitor banks (or Static var generator/Active harmonic filter)can be installed at 3 different levels. 1.Global installation Advantages: - No reactive energy bill. - Represents the most economical solution since all the power is concentrated at one point and the expansion coefficient makes it possible to optimize banks - Relieves the transformer. Remark:...
read more
-
Nov 23,2019
var The unit of measurement for reactive power. Active power (P) Active power is the useful power that does the actual work. Active power is measured in W, kW, MW. Reactive power (Q) Reactive power is a product of an AC system. Reactive power is used to produce magnetic fields. Reactive power is mea- sured in var, kvar, Mvar. Apparent power (S) Apparent power or total power is a combination of act...
read more
-
Nov 23,2019
Rated insulation level The combination of voltage values that characterizes the insulation of the equipment with regard to its capability to withstand dielectric stresses. These values are selected based on the rated voltage of the bank/system. Standard insulation values are given for altitudes <1000 m above sea level. For higher altitudes, a correction factor must be used. Lightning impulse te...
read more
-
Nov 25,2019
Manufacture of power quality solutions,ZDDQ ensuring stronger, smarter and greener grids Power quality is a major concern for transmission and distribution utilities, industries, and transport and infrastructure sectors. Poor power quality affects grid reliability, productivity, leads to higher operating costs and penalties for non-compliance with grid codes. ZDDQ is a technology leader with a wid...
read more
-
Nov 28,2019
Standard Features Enclosure ZDDQ Capacitor banks,free standing, compartmentalized, all welded, galvanneal steel construction with 3 point pad-lockable latching handles and stainless steel hinges. The enclosure is painted with a corrosion resistant ANSI gray-61 epoxy paint. NEMA 3R construction is standard; NEMA 12 and 4X are available as an option. Base of enclosure as well as capacitor supports a...
read more
-
Dec 05,2019
Typical non-linear loads We will be focusing on the six pulse rectifier bridge. The 3 phase rectifier has a key role to play because a significant portion of the electrical energy is drawn from loads with this type of front-end circuit. One typical application that can be mentioned is the variable speed motor drive, which has been used for years with high growth rates in almost every industrial se...
read more
-
Dec 05,2019
What's the Definition of Power Factor? Power Factor Definition: Power factor(PF for short) is the ratio between KW and KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively the current is being converted into useful work output and more particularly is a good indicator of the effect of the load current on th...
read more
-
Dec 07,2019
Active Harmonic Filter Active Harmonic Filter has many potential applications where its use can offer plenty of benefits. Active Harmonic Filters have been proven to provide lowered disturbances, lower carbon dioxide emissions through improved energy efficiency, lower current consumption and increased production stability to name a few. Just as other technology has evolved, so have various product...
read more
-
Dec 10,2019
What is Static Var Generator? Static Var Generator (SVG) also known as instantaneous stepless reactive power compensators or active power factor compensators (APFC),are the ultimate solution to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications. SVG is a high performance, compact, flexible, modular and cost-effectiv...
read more
-
Dec 18,2019
Single busbar compensation Overview An installation with a single LV busbar is that most often encountered. This type of installation requires that the reactive power can change with respect to the methods defined previously. Compensation uses all the receiving devices of the installation and the amperage of the current transformer is determined according to the total current conducted through the...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 1 Selection of the compensation mode The location of L.V capacitors banks in an installation constitutes the mode of reactive power compensation, which may be central (one location for the entire installation), by sector or group (section-by-section), at load level, or some combination of the latter two. In principle, th...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 2 Selection of the compensation type Different types of compensation should be adopted depending on the performance requirements and complexity of control: Fixed, by connection of a fixed-value capacitor bank Automatic, by connection of a different number of steps, allowing adjustment of the reactive energy to the requir...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 3: Allowance for operating conditions and harmonics Capacitor banks should be selected depending on the working conditions expected during their lifetime. Allowing for operating conditions The operating conditions have a great influence on the life expectancy of capacitors. The following parameters should be taken into a...
read more
-
Dec 23,2019
The Graph below shows Harmonic Current Distortion in the form of THDi. This is hovering between 20 and 25%. Ideally, it should be less than 10% and preferably less than 8% THDi. The highest value of average total harmonic distortion (THDi%) across three phases was calculated from raw data. This value is 24.19%THDi and was recorded at time shown. At the same time, average line current (Amps) across...
read more
-
Dec 28,2019
Reactive power is necessary to generate magnetic fields, e.g. in motors, transformers and generators. This power oscillates between the source and the load and represents an additional loading. Static var Compensator (SVC) and static var generator can suppress the voltage fluctuation, flicker and rapidly compensate the reactive power and the quality of electric power can be improved. If you have q...
read more