Sep 19,2019
Anhui Zhongdian(ZDDQ) Electric Co., Ltd. established in 2001. ZDDQ Technology Park locates in Bengbu City of Anhui Provice. We're a professional and leading manufacture, focus on advanced power quality solutions and power factor correction. APF,SVG,APFC are our main products. ZDDQ have a leading independent R&D team and quality supervision system, and maintain long-term cooperative relations w...
read more
-
Dec 10,2019
What is Static Var Generator? Static Var Generator (SVG) also known as instantaneous stepless reactive power compensators or active power factor compensators (APFC),are the ultimate solution to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications. SVG is a high performance, compact, flexible, modular and cost-effectiv...
read more
-
Dec 28,2019
Reactive power is necessary to generate magnetic fields, e.g. in motors, transformers and generators. This power oscillates between the source and the load and represents an additional loading. Static var Compensator (SVC) and static var generator can suppress the voltage fluctuation, flicker and rapidly compensate the reactive power and the quality of electric power can be improved. If you have q...
read more
-
Jan 04,2020
SVG Principle The principle of the SVG is, when the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. Compare...
read more
-
Jan 16,2020
There are a couple of principles to achieve reactive power compensation. The simplest solution is without any doubts a combination of switched passive elements, i.e. switched capacitors and inductors. Figure 1 shows qualitatively the reactive current versus connected voltage of such a solution. The reactive current depends linearly on the grid voltage and as a consequence the reactive power change...
read more
-
Jan 17,2020
Centralised compensation Centralised compensation by means of an automatic capacitor bank with automatic regulation offers the most simple and economical solution. The reactive power is subdivided in a number of capacitor steps that can be connected independently. A reactive power controller continuously measures the needs of the installation and connects or disconnects the capacitors until the ta...
read more
-
Feb 04,2020
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 10,2020
WHAT IS HARMONIC FILTERING? To understand the purpose of harmonic filtering, it helps to understand what harmonics are. The voltage of a standard 50Hz Alternating Current(AC) power supply swings between positive and negative 50 times a second, following a neat sine-wave. Linear AC electrical loads such as heaters or incandescent lights draw a current that follows this same sine-wave. The graph abo...
read more
-
Feb 18,2020
How much can be saved? Ultimately the level of energy saving achieved will be dictated by a combination of the incoming supply voltage level and the types of electrical equipment in use. The higher the supply voltage, the greater the potential to make energy savings. However different types of electrical equipment deliver different levels of energy saving for the same reduction in voltage. Voltage...
read more
-
Feb 21,2020
Medium Voltage STATCOM-Dynamic Reactive Compensation -----Providing stability, security, and reliability to the grid Installing a STATCOM at one or more suitable points on the network is a powerful and cost effective method to increase grid transfercapability and enhance voltage stability. What is a STATCOM? A STATCOM (or Static Synchronous Compensator) is a voltage regulating device. It is based ...
read more
-
Feb 29,2020
The ubiquity of synchronous generation should not be assumed in highly renewable power systems. Various problems may consequently arise, not least of which are the difficulties entailed in maintaining regional reactive power balance. Offering a potential solution to such problems, modern renewable generator technologies offer controllable reactive power resources. As many of these generators will ...
read more
-
Mar 04,2020
STATCOM - Static Synchronous Compensator It is a solid-state switching converter, capable of generating or absorbing independently controllable real and reactive power at its output terminals when it is fed from an energy source. STATCOM is considered as voltage-source converter that, from a given input of dc voltage, produces a set of 3-phase ac-output voltages, each in phase with and coupled to ...
read more
-
Mar 23,2020
Overview of Active Power Filter APF-1000 APF-1000 Active power filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensation, and the proportion of compensation capacity by harmonic, reactive power, and three-phase unbalance can also be set, comprehensively solving the problem of ...
read more
-
Apr 24,2020
Following are simple contrast list, Product Static Var Generator(SVG) Multifunctional electricity controller & optimizer (MEC) Mechanical switch capacitor (MSC) Thyristor-switched capacitor (TSC) Response speed ≤5ms ≤5ms 300ms 20ms Reactive power compensation ability Rated capacitive reactive power to rated inductive reactive power, 0.1kVar precision, and up to 1 power factor Rated capacitive ...
read more
-
Apr 29,2020
STATCOM A static synchronous compensator, known as a STATCOM, is another device used to regulate the power factor in medium to high voltage applications. They operate on roughly the same principles as a synchronous compensator, however, use a voltage source converter as opposed to a rotating machine to provide dynamic Power Factor Correction. STATCOMs use IGBT switching te...
read more
-
May 06,2020
ZDDQ 690V Static Var Generator ZD-SVGM-2000 Static Var Generator (SVG) is the new standard in reactive energy compensation for 690V networks. This power electronic current source is the accurate and highly reliable solution for today’s networks characterised by significant increase in harmonics, voltage variations caused by intermittent renewable sources connected to the network and voltage level ...
read more
-
May 13,2020
High Power STATCOM in Electricity Networks A High Power STATCOM is usually installed to support electricity networks that have a poor power factor and often poor voltage regulation. STATCOM –static synchronous compensator – is a solution often deployed by utilities or large industries to solve flicker, harmonic and dynamic reactive compensation problems in medium voltage or high voltage netw...