Sep 19,2019
Anhui Zhongdian(ZDDQ) Electric Co., Ltd. established in 2001. ZDDQ Technology Park locates in Bengbu City of Anhui Provice. We're a professional and leading manufacture, focus on advanced power quality solutions and power factor correction. APF,SVG,APFC are our main products. ZDDQ have a leading independent R&D team and quality supervision system, and maintain long-term cooperative relations w...
read more
-
Nov 22,2019
Based on the power of a receiver in kW, this table can be used to calculate the power of the capacitors to change from an initial power factor to a required power factor. It also gives the equivalence between cosΦ tanΦ,
read more
-
Nov 22,2019
In an L.V/M.V/H.V electrical installation, capacitor banks (or Static var generator/Active harmonic filter)can be installed at 3 different levels. 1.Global installation Advantages: - No reactive energy bill. - Represents the most economical solution since all the power is concentrated at one point and the expansion coefficient makes it possible to optimize banks - Relieves the transformer. Remark:...
read more
-
Nov 23,2019
Rated insulation level The combination of voltage values that characterizes the insulation of the equipment with regard to its capability to withstand dielectric stresses. These values are selected based on the rated voltage of the bank/system. Standard insulation values are given for altitudes <1000 m above sea level. For higher altitudes, a correction factor must be used. Lightning impulse te...
read more
-
Dec 07,2019
Active Harmonic Filter Active Harmonic Filter has many potential applications where its use can offer plenty of benefits. Active Harmonic Filters have been proven to provide lowered disturbances, lower carbon dioxide emissions through improved energy efficiency, lower current consumption and increased production stability to name a few. Just as other technology has evolved, so have various product...
read more
-
Dec 10,2019
What is Static Var Generator? Static Var Generator (SVG) also known as instantaneous stepless reactive power compensators or active power factor compensators (APFC),are the ultimate solution to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications. SVG is a high performance, compact, flexible, modular and cost-effectiv...
read more
-
Dec 18,2019
Single busbar compensation Overview An installation with a single LV busbar is that most often encountered. This type of installation requires that the reactive power can change with respect to the methods defined previously. Compensation uses all the receiving devices of the installation and the amperage of the current transformer is determined according to the total current conducted through the...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 1 Selection of the compensation mode The location of L.V capacitors banks in an installation constitutes the mode of reactive power compensation, which may be central (one location for the entire installation), by sector or group (section-by-section), at load level, or some combination of the latter two. In principle, th...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 2 Selection of the compensation type Different types of compensation should be adopted depending on the performance requirements and complexity of control: Fixed, by connection of a fixed-value capacitor bank Automatic, by connection of a different number of steps, allowing adjustment of the reactive energy to the requir...
read more
-
Dec 25,2019
We make a simple introduction about harmoincs in networks,welcome to communicate with us about harmonics and how to solve. General Introduction Harmonics are usually defined by two main characteristics: Their amplitude: value of the harmonic voltage or current. Their order: value of their frequency with respect to the fundamental frequency (50 Hz). Under such conditions, the frequency of a 5th ord...
read more
-
Dec 28,2019
Reactive power is necessary to generate magnetic fields, e.g. in motors, transformers and generators. This power oscillates between the source and the load and represents an additional loading. Static var Compensator (SVC) and static var generator can suppress the voltage fluctuation, flicker and rapidly compensate the reactive power and the quality of electric power can be improved. If you have q...
read more
-
Jan 02,2020
The effects of harmonics on loads The following two types of effects appear in the main equipment: immediate or short-term effects and long-term effects. Immediate or short-term effects: Unwanted tripping of protection devices, Induced interference from LV current systems (remote control, telecommunications), Abnormal vibrations and noise, Damage due to capacitor thermal overload, Faulty operation...
read more
-
Jan 03,2020
Compared with SVC, SVG is superior to SVC in the following aspects: SVG: Static Var Generator(also as know static synchronous compensator or Statcom) SVC: Static Var Compensator 1. Advanced working principle (1)Static Var Compensator can be seen as a dynamic source of reactive power. According to the requirements of accessing the grid, it can provide capacitive reactive power to networks, and...
read more
-
Jan 04,2020
SVG Principle The principle of the SVG is, when the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. Compare...
read more
-
Jan 13,2020
Abstract: The application of SVG/STATCOM, a high voltage dynamic reactive power compensation device, produced by ZDDQ Electric Co., Ltd. is described in this paper. Its role in reactive power compensation for new energy construction is analyzed and its applications in electric and electronic fields are indicated. Key words: SVG;STATCOM; Photovoltaic station; Reactive power compensation; Applicatio...
read more
-
Jan 16,2020
There are a couple of principles to achieve reactive power compensation. The simplest solution is without any doubts a combination of switched passive elements, i.e. switched capacitors and inductors. Figure 1 shows qualitatively the reactive current versus connected voltage of such a solution. The reactive current depends linearly on the grid voltage and as a consequence the reactive power change...
read more
-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 12,2020
A capital investment in power factor correction(STATCOM or SVC) and harmonic filtering equipment can result in a healthy return of investment –depending on the utility’s demand rate structure, production quality cost due to harmonics and voltage fluctuations in the distribution system. ZDDQ Electric power quality correction products are part of the solution. Most utilities charge for peak electric...