Nov 22,2019
STATCOM/SVG INTRODUCTION Static Synchronous Compensator STATCOM (SVG) is one of the core equipment FACTS (Flexible Alternative Current Transmission Systems).The system can quickly compensate reactive, and take effective governance for harmonics, voltage fluctuations and flicker and other power quality problems, improve the safety and reliability of the system. With the limits of the IGBT can withs...
read more
-
Nov 22,2019
In an L.V/M.V/H.V electrical installation, capacitor banks (or Static var generator/Active harmonic filter)can be installed at 3 different levels. 1.Global installation Advantages: - No reactive energy bill. - Represents the most economical solution since all the power is concentrated at one point and the expansion coefficient makes it possible to optimize banks - Relieves the transformer. Remark:...
read more
-
Nov 23,2019
var The unit of measurement for reactive power. Active power (P) Active power is the useful power that does the actual work. Active power is measured in W, kW, MW. Reactive power (Q) Reactive power is a product of an AC system. Reactive power is used to produce magnetic fields. Reactive power is mea- sured in var, kvar, Mvar. Apparent power (S) Apparent power or total power is a combination of act...
read more
-
Nov 29,2019
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Dec 18,2019
Single busbar compensation Overview An installation with a single LV busbar is that most often encountered. This type of installation requires that the reactive power can change with respect to the methods defined previously. Compensation uses all the receiving devices of the installation and the amperage of the current transformer is determined according to the total current conducted through the...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 1 Selection of the compensation mode The location of L.V capacitors banks in an installation constitutes the mode of reactive power compensation, which may be central (one location for the entire installation), by sector or group (section-by-section), at load level, or some combination of the latter two. In principle, th...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 2 Selection of the compensation type Different types of compensation should be adopted depending on the performance requirements and complexity of control: Fixed, by connection of a fixed-value capacitor bank Automatic, by connection of a different number of steps, allowing adjustment of the reactive energy to the requir...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 3: Allowance for operating conditions and harmonics Capacitor banks should be selected depending on the working conditions expected during their lifetime. Allowing for operating conditions The operating conditions have a great influence on the life expectancy of capacitors. The following parameters should be taken into a...
read more
-
Dec 28,2019
Reactive power is necessary to generate magnetic fields, e.g. in motors, transformers and generators. This power oscillates between the source and the load and represents an additional loading. Static var Compensator (SVC) and static var generator can suppress the voltage fluctuation, flicker and rapidly compensate the reactive power and the quality of electric power can be improved. If you have q...
read more
-
Jan 03,2020
Compared with SVC, SVG is superior to SVC in the following aspects: SVG: Static Var Generator(also as know static synchronous compensator or Statcom) SVC: Static Var Compensator 1. Advanced working principle (1)Static Var Compensator can be seen as a dynamic source of reactive power. According to the requirements of accessing the grid, it can provide capacitive reactive power to networks, and...
read more
-
Jan 04,2020
SVG Principle The principle of the SVG is, when the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. Compare...
read more
-
Jan 07,2020
Part 1:Principle of reactive energy management All AC electrical networks consume two types of power: active power (kW) and reactive power (kVAr): The active power P (in kW) is the real power transmitted to loads such as motors,lamps, heaters, computers, etc. The electrical active power is transformed into mechanical power, heat or light. The reactive power Q (in kVAr) is used only to power the ma...
read more
-
Jan 13,2020
Abstract: The application of SVG/STATCOM, a high voltage dynamic reactive power compensation device, produced by ZDDQ Electric Co., Ltd. is described in this paper. Its role in reactive power compensation for new energy construction is analyzed and its applications in electric and electronic fields are indicated. Key words: SVG;STATCOM; Photovoltaic station; Reactive power compensation; Applicatio...
read more
-
Jan 16,2020
There are a couple of principles to achieve reactive power compensation. The simplest solution is without any doubts a combination of switched passive elements, i.e. switched capacitors and inductors. Figure 1 shows qualitatively the reactive current versus connected voltage of such a solution. The reactive current depends linearly on the grid voltage and as a consequence the reactive power change...
read more
-
Jan 17,2020
Centralised compensation Centralised compensation by means of an automatic capacitor bank with automatic regulation offers the most simple and economical solution. The reactive power is subdivided in a number of capacitor steps that can be connected independently. A reactive power controller continuously measures the needs of the installation and connects or disconnects the capacitors until the ta...
read more
-
Jan 19,2020
A changing electrical network brings new power quality issues. Today the way we generate, use, and control our energy is changing. New and renewable generation and distribution technology is becoming common, and combined with more dynamic and complex load profiles, there are more challenges faced by the network and energy users to provide high power quality. A new way to improve your power quality...
read more
-
Feb 01,2020
To our clients, You may have had some good memories about the past one, but you never know what’s the new one is bringing for you. It's time to be hopeful, have new dreams and make some new resolutions for the new year in your life. It's time to connect with each other and make new year wishes. Its time to move on and embrace what’s new. New year means a lot of new dreams and new achievements. Peo...
read more
-
Feb 21,2020
Medium Voltage STATCOM-Dynamic Reactive Compensation -----Providing stability, security, and reliability to the grid Installing a STATCOM at one or more suitable points on the network is a powerful and cost effective method to increase grid transfercapability and enhance voltage stability. What is a STATCOM? A STATCOM (or Static Synchronous Compensator) is a voltage regulating device. It is based ...
read more