-
May 20,2020
STATCOM STATCOM (Static Synchronous Compensator)continuously provides variable reactive power in response to voltage variations, supporting the stability of the grid. STATCOM operates according to voltage source converter (VSC) principles, combining unique PWM (pulse width modulation) with millisecond switching. STATCOM functions with a very limited need for harmonic filters, contributing to a sma...
read more
-
Jun 06,2020
Overview A New Generation in Power Factor Correction Today's automation equipment benefits us with greater convenience as well as cost savings from higher production efficiency. However, it can also bring significant wave distortion problems to the power grid that can lead to energy loss, increasing costs and many other power quality issues. A clean and efficient power system normally generates a ...
read more
-
Jun 29,2020
The nature of transformer inductive reactances All previous references have been to shunt connected devices such as those used in normal loads, and power factor correction capacitor banks etc. The reason for this is that shunt connected equipment requires (by far) the largest quantities of reactive energy in power systems; however, series-connected reactances, such as the inductive reactances of p...
read more
-
Jul 17,2020
Problem High Electricity Bills in Steel Factory. Analysis To analyze the power quality at Steels Factory and to understand the Voltage, Current, Power Factor, Active power,Reactive power, Apparent power, THD profile and to suggest the required solution to improve Power Factor, to qualify for Utility PF incentive. Towards fulfilling the need, fixed Capacitor bank of 2400KVAr has been installed at 1...
read more
-
Jul 27,2020
Overview ZD-MCJB Medium voltage automatic power factor controller and protection Unit Our R&D has developed MV automatic power factor controller and protection unit since May 2019, and has intalled in many sites an d has a very good running. Now we introduce our MV auto PF controller and protection unit officially. ZD-MCJB PF controller and protection unit is suitable for automatically adjusti...
read more
-
Aug 03,2020
Low Power Factor Operation of Induction Motor Induction Motors finds various applications in industries and household equipments. Such machine requires magnetic fields for its functioning hence, it draws magnetizing current from the source. The magnetizing current is the current that establishes the flux in the air gap of an Induction motor and this is independent of the load on the motor. It is t...
read more
-
Sep 08,2020
Leading Provider of Technology One of the Leading Static Var Generator manufacturing base in China Exclusive to +/-100Mvar Statcom R&D manufacture Advanced and strong R&D center Patents Owner Based on IGBT National Industry standards drafters CE Certificate 101 national patens 1 national science and technology invention award Advanced Technologies Perfect Auto-diagnosis at Starting Stage D...
read more
-
Sep 15,2020
Leaders in Power Quality Solutions ZDDQ is one of leading manufacturers of power quality solutions from China. Here at ZDDQ we believe in creating and maintaining the highest quality power possible for our customers through an indepth understanding of power usage and electrical efficiencies. We source world’s best components to manufacture custom solutions to reduce maintenance and energy costs. N...
read more
-
Sep 24,2020
480V power quality solutions has the best compatibility for low voltage grid(3 phase 4 wire).ZDDQ has full series 480V devices for power quality improvement and power factor correction. 480V Active Power Filter Active Power Filter has various compensation modes (harmonic, reactive power, three-phase unbalance and capacitor switching control), which can simultaneously make the said various compensa...
read more
-
Oct 04,2020
During 1st quarter in 2020, for the reason of Covid-19, Medium Voltage STATCOM projects are delayed or stopped in China. But from March, the conditions has been better and the projects status has been normal from the 2nd quarter. From the 2nd quarter to now,we have finished installatlion and commissioning of some Medium voltage Stacom projects, such as 10kv/4Mvar, 10kv/2Mvar, 35kv/12Mvar, 10k...
read more
-
Oct 21,2020
Our Indian Clients and African Clients has installed hybrid reactive power compensation system. After our guide, they use ZDDQ SVG mixed with Capapacitor banks based on Contactors and Thyristors. A united system of thyristor switched capacitor (TSC) and static var generator (SVG) was proposed to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. Th...
read more
-
Oct 30,2020
Our low voltage Static Var Generator has widely installed in many countries and has a good function and quality performance. In some countries, client use our SVG to compensate reactive power together with their capacitor banks, which is named as hybrid compensation system. In some countries, our SVG are used for power factor correction at the site where the load changes fast and frequently. And s...
read more
-
Nov 23,2020
ZDDQ Static Var Generator SVG and Active Power Filter APF adopt dual interface of Current Transformer,which has great to facilitate new project design and adaptation to old projects. Our SVG and APF can accurately calculate the load harmonic current data and provide perfect compensation effect. For following sites, Both single module or multiple modules in parallel, Multiple active filter/SVGcabin...
read more
-
Dec 09,2020
The static var generator (SVG) with appropriate control method is a good solution to solve the problem of reactive power impact and harmonic pollution which is generated by the nonlinear load. A control strategy using active current separation and the current indirect control is used for SVG. The active current separation is a method for detecting the harmonic and reactive current, and then the su...
read more
-
Dec 22,2020
SVG: Static Var Generator ANHUI ZHONGDIAN ELECTRIC CO., LTD. static var generator is a static electrical device/equipment/system that draws controlled capacitive or inductive current from the electrical power system and thereby generates or absorbs reactive power. Permanently connected and switchable reactor and capacitor banks have been always used in AC power systems to ensure desirable voltages...
read more
-
Jan 05,2021
Research A recent ZDDQ survey shows that the global static VAR generator market is projected to grow remarkably owing to the persistent demand for stable power supply from the consumers. Knowing from Fortune Business Insights, in an upcoming report, titled, “Static VAR Generator“ Market Size, Share & Industry Analysis, By Type (Thyristor Based, MCR Based), By End-User (Electric Utility, Renewa...
read more
-
Jan 21,2021
ZDDQ Engineers give an example for reference, An Alternator is supplying a load of 650 kW at Power factor 0.65. What size of Capacitor banks (kVAR) is required to raise the Power Factor to unity (1 or >0.95)? And how many more kW can the alternator supply for the same kVA loading when P.F improved. Supplying kW = 650 kW Original P.F = Cosθ1 = 0.65 Final P.F = Cosθ2 = 1 θ1 = Cos-1 = (0.65) = 49°...
read more
-
Feb 03,2021
HV/MV Power factor correction is directly related to the different aspects that assist the technical management of transport and distribution networks. These are: Power quality This involves the increase in the levels of voltage in substation busbars and line ends. Optimisation of the installation's cost of operation In other words, the decrease of the reactive energy and, therefore, the reduction...
read more