Nov 29,2019
Industry background Chemical industry involves many mechanical processes with demanding quality requirements. Before any mechanical smelting, casting, or stamping, an induction melting furnace is used to melt metal. Most induction melting furnaces use a 6-pulse or 12-pulse rectifier, which produces high volumes of harmonic and reactive power. As a result, the production efficiency of induction mel...
read more
-
Dec 05,2019
What's the Definition of Power Factor? Power Factor Definition: Power factor(PF for short) is the ratio between KW and KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively the current is being converted into useful work output and more particularly is a good indicator of the effect of the load current on th...
read more
-
Dec 18,2019
Single busbar compensation Overview An installation with a single LV busbar is that most often encountered. This type of installation requires that the reactive power can change with respect to the methods defined previously. Compensation uses all the receiving devices of the installation and the amperage of the current transformer is determined according to the total current conducted through the...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 1 Selection of the compensation mode The location of L.V capacitors banks in an installation constitutes the mode of reactive power compensation, which may be central (one location for the entire installation), by sector or group (section-by-section), at load level, or some combination of the latter two. In principle, th...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 2 Selection of the compensation type Different types of compensation should be adopted depending on the performance requirements and complexity of control: Fixed, by connection of a fixed-value capacitor bank Automatic, by connection of a different number of steps, allowing adjustment of the reactive energy to the requir...
read more
-
Dec 19,2019
Method for determining compensation (Power Factor correction Guidelines) Step 3: Allowance for operating conditions and harmonics Capacitor banks should be selected depending on the working conditions expected during their lifetime. Allowing for operating conditions The operating conditions have a great influence on the life expectancy of capacitors. The following parameters should be taken into a...
read more
-
Dec 23,2019
The Graph below shows Harmonic Current Distortion in the form of THDi. This is hovering between 20 and 25%. Ideally, it should be less than 10% and preferably less than 8% THDi. The highest value of average total harmonic distortion (THDi%) across three phases was calculated from raw data. This value is 24.19%THDi and was recorded at time shown. At the same time, average line current (Amps) across...
read more
-
Jan 10,2020
STATCOM will be utilized in the night for power factor correction and voltage control at the terminals of an induction motor operating at poor power factor. PV solar farms produce power during the day and are completely idle in the nights. The proposed new control on PV solar system will help in increase the utilization of the PV solar system. A key component of the PV solar plant is a voltage sou...
read more
-
Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 29,2020
The ubiquity of synchronous generation should not be assumed in highly renewable power systems. Various problems may consequently arise, not least of which are the difficulties entailed in maintaining regional reactive power balance. Offering a potential solution to such problems, modern renewable generator technologies offer controllable reactive power resources. As many of these generators will ...
read more
-
Apr 18,2020
Power quality problems and Industry background Dynamic reactive power, lower power factors, and higher harmonic content are common power quality problems in the CNC industry. Major contamination sources of power quality include the punching machines,welding machines. When harmonics occur, dynamic reactive current and 3-phase imbalance are produced. During the CNC period, the power factor of arc fu...
read more
-
May 13,2020
High Power STATCOM in Electricity Networks A High Power STATCOM is usually installed to support electricity networks that have a poor power factor and often poor voltage regulation. STATCOM –static synchronous compensator – is a solution often deployed by utilities or large industries to solve flicker, harmonic and dynamic reactive compensation problems in medium voltage or high voltage netw...
read more
-
Jun 06,2020
Overview A New Generation in Power Factor Correction Today's automation equipment benefits us with greater convenience as well as cost savings from higher production efficiency. However, it can also bring significant wave distortion problems to the power grid that can lead to energy loss, increasing costs and many other power quality issues. A clean and efficient power system normally generates a ...
read more
-
Jul 17,2020
Problem High Electricity Bills in Steel Factory. Analysis To analyze the power quality at Steels Factory and to understand the Voltage, Current, Power Factor, Active power,Reactive power, Apparent power, THD profile and to suggest the required solution to improve Power Factor, to qualify for Utility PF incentive. Towards fulfilling the need, fixed Capacitor bank of 2400KVAr has been installed at 1...
read more
-
Nov 11,2020
With our best quality of our products and good relationship in the power quality field, we just received an important order for medium voltage capacitor banks. Backgroud. The rated voltage is 10kv. The total capacity is 35.4Mvar. There are individual type capacitor banks, central capacitor banks. Also there are fixed capacitor banks, and mulitipl-step automatic capacitor banks. As we know, STATCOM...
read more
-
Nov 30,2020
Relations between Reactive power,power factor and penalty Power Factor penalty is spelled out in the contract between the Power Company and Industrial or Commercial customer with large three phase loads. If the contract calls for 85% Power Factor, once the customer’s power factor falls below 85%, the Power Company bills the Customer according to the agreed penalty rates. Industrial loads are mostl...
read more
-
Dec 18,2020
Introduction From ZDDQ professional engineers: Power systems are designed to operate at frequencies of 50 or 60Hz. However, certain types of loads produce currents and voltages with frequencies that are integer multiples of the 50 or 60 Hz fundamental frequency. These higher frequencies are a form of electrical pollution known as power system harmonics. Solution ZD-APF(Active Power Filter). This i...
read more
-
Jan 16,2021
Status analysis According to marketing research by ZDDQ(ANHUI ZHONGDIAN ELECTRC CO., LTD.). To reduce energy consumption and increase energy efficiency, many facility management executives are looking to renewable energy sources, such as solar or wind, to offset reliance on traditional electric power. Despite the growing prevalence of these solutions, there are drawbacks that can make alternative ...
read more