Jan 27,2021
Overview ZDDQ Active Power Filter have exported to many countries all over the world. These filters are widely used in a number of industries such as oil & gas, manufacturing, water/wastewater, metal and mining, and paper and pulp. A harmonic filter is used to mitigate harmonics created by non-linear loads in electrical equipment. Classification Ⅰ. Product Insights Based on product type, ...
read more
-
Feb 03,2021
HV/MV Power factor correction is directly related to the different aspects that assist the technical management of transport and distribution networks. These are: Power quality This involves the increase in the levels of voltage in substation busbars and line ends. Optimisation of the installation's cost of operation In other words, the decrease of the reactive energy and, therefore, the reduction...
read more
-
Mar 08,2021
High Voltage Power Capacitors Fields of Application INDIVIDUAL POWER FACTOR CORRECTION The power factor correction capacitor is connected directly to the terminals of the consumer and will be switched together with it. Advantages of individual capacitors at the load: • Complete control; capacitors cannot cause problems on the line during light load conditions • No need for separate switching...
read more
-
Mar 20,2021
A capacitor bank is a grouping of several identical capacitors interconnected in parallel or in series with one another. These groups of capacitors are typically used to correct or counteract undesirable characteristics, such as power factor lag or phase shifts inherent in alternating current (AC) electrical power supplies. FEATURES: Power factor correction by multi step design Standard & detu...
read more
-
Apr 12,2021
Power Quality Solutions and Energy Savings One of the most significant changes in the Power Quality industry in the past five years is the method of selling Power Quality solutions. Originally, Power Quality solutions were sold as an insurance policy to avoid potential damage from power disturbances such as transients,voltage sags, interruptions or harmonics. Today, many Power Qu...
read more
-
Apr 17,2021
Many facilities have mandates to save energy. Improving energy efficiency offers huge advantages to businesses—reducing the costs of energy and operations— and increasing sustainability. Ⅰ. Abstract Through proven methods including variable frequency drives (VFD), LED lighting and conservation methods and control, many new and existing facilities achieve the savings that they expect. However, many...
read more
-
Apr 26,2021
Power Factor Penalty An electric rate may also include additional charges when the customer has a power factor less than some preset limit, typically between 80 and 90 percent. This is called a power factor penalty since it is a penalty assessed on the customers electrical bill for lower than optimum power factor. Special devices called capacitors can be installed by either the utility or the cust...
read more
-
Jun 16,2021
Power factor penalty in power bills We've found that many people struggle to understand how Power Factor (PF) impacts demand charges. Frequently, end use customers pay a significant premium each month in demand charges because their PF is below a threshold set by the utility in the rate tariff. Oftentimes its not obvious to the untrained eye when there are extra charges associated with a bad PF on...
read more
-
Oct 15,2021
Overview Rapid growth of inductive electric loads on utility networks has impacted the efficient operation of AC electrical transmission and distribution grid by increasing the need for reactive power (VAr/kVAr/MVAr) that are required to be supplied with active power. Install capacitor banks to reduce the reactive power demand from point of generation to point of use in high voltage networks. Brin...
read more
-
Jan 10,2022
ZDDQ Low Voltage Capacitor Bank for Reactive Power Compensation Reactive power compensation, is a technology that improves the power factor of the power grid in the power supply system, reduces the loss of power supply transformers and transmission lines, improves power supply efficiency, and improves the power supply environment. Therefore, the reactive power compensation device is in an indispen...
read more
-
May 27,2022
ZDDQ low voltage automatic capacitor banks improves power factor in networks with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equip...
read more
-
Jun 10,2022
Harmonic Mitigation Expert---Active Power Filter The main hazards of harmonics: Increase the load of power facilities, reduce the power factor of the system, reduce the effective capacity and efficiency of power generation, transmission and power consumption equipment, resulting in equipment waste, line waste and power loss; Causes the resonance of reactive power compensation capacitors and the am...
read more
-
Jul 05,2022
Step–less reactive compensator –STATCOM Static Synchronous Compensator (STATCOM) hasearned its name as it does not have any rotating or moving parts, and yet offers a fast and step-less reactive compensation. It is based on voltage source converter (VSC) technology, which uses low-voltagecells in series to realise a high voltage output By controlling the output voltage to be either higher or lower...
read more
-
Aug 22,2022
The application of distribution system capacitor banks has long been accepted as a necessary step in the design of distribution feeders. Design considerations often include traditional factors such as voltage support, power factor, and released capacity. However, as customer systems evolve through the use of power electronics, the distribution system design of the future will include power quality...
read more
-
Sep 29,2022
The ZDDQ SVG module we exported to Colombia in mid-September has been put into use and installed in an airport power distribution room somewhere in Bogota, and the compensation effect is good. The two modules are: 440V 60Hz 40kvar(50A) SVG Module and 440V 60Hz 80kvar(100A) SVG Module.
read more
-
Dec 05,2022
Reactive Power in Inductive Loads Inductive loads such as chokes, motors, inductive heating equipment, generators, transformers, and arc welding equipment produce an electrical lag that is commonly referred to as inductance. This inductance causes a phase difference between current and voltage. As a result of phase shift due to inductance, there are times when current and voltage have different si...
read more
-
Mar 06,2023
ZDDQ Active Power Filters exported to Thailand. We have been cooperating with this customer for almost 3 years. The quality of our Active Power Filter is stable, the technical and market performance is excellent, the order demand of the customer is stable, and we have formed a relatively good reputation in the market. Thanks for Client's trust and support.Not more than 2 months, this new order is ...
read more
-
Mar 27,2023
In low voltage distribution system, usually two solutions for the power factor correction: capacitor bank and static var generator. Low Voltage Capacitor Bank The load current provided by the grid to the electrical equipment is composed of active current and reactive current. The reactive current is exchanged between the power supply and the load, which greatly occupies the grid, greatly reduces t...
read more