Feb 07,2020
Power Factor Correction The active power produced by the active current can alone be turned into an effective use for the consumer; while the reactive power produced by the reactive current does not yield usable power, and consequently, is not registered on the active performance meter. The reactive power has, however, a negative effect on generators, transformers, and conductor lines, while causi...
read more
-
Feb 12,2020
A capital investment in power factor correction(STATCOM or SVC) and harmonic filtering equipment can result in a healthy return of investment –depending on the utility’s demand rate structure, production quality cost due to harmonics and voltage fluctuations in the distribution system. ZDDQ Electric power quality correction products are part of the solution. Most utilities charge for peak electric...
read more
-
Feb 29,2020
The ubiquity of synchronous generation should not be assumed in highly renewable power systems. Various problems may consequently arise, not least of which are the difficulties entailed in maintaining regional reactive power balance. Offering a potential solution to such problems, modern renewable generator technologies offer controllable reactive power resources. As many of these generators will ...
read more
-
Mar 04,2020
STATCOM - Static Synchronous Compensator It is a solid-state switching converter, capable of generating or absorbing independently controllable real and reactive power at its output terminals when it is fed from an energy source. STATCOM is considered as voltage-source converter that, from a given input of dc voltage, produces a set of 3-phase ac-output voltages, each in phase with and coupled to ...
read more
-
Mar 28,2020
Power quality “Power quality” can seem to be a pretty abstract term – how does one judge the quality of such an unseen commodity as electricity? But, as commercial and industrial facility managers know, good power quality can boost both productivity and employee safety, while poor power quality can mean a drain on the bottom line, thanks to damaged equipment, lost productivity and product spoilage...
read more
-
Apr 13,2020
Voltage Sag Voltage sag is the main problem to cause the losses of industrial production. Unpredictable outage rarely happen in many high automated process control industries. who have the good power supplies. Voltage Sag is mostly caused by thunder,but it also has other reasons. Power system cause: starting of heavy machine and short circuit fault. Unpredictable accident:traffic accident,construc...
read more
-
May 20,2020
STATCOM STATCOM (Static Synchronous Compensator)continuously provides variable reactive power in response to voltage variations, supporting the stability of the grid. STATCOM operates according to voltage source converter (VSC) principles, combining unique PWM (pulse width modulation) with millisecond switching. STATCOM functions with a very limited need for harmonic filters, contributing to a sma...
read more
-
Nov 30,2020
Relations between Reactive power,power factor and penalty Power Factor penalty is spelled out in the contract between the Power Company and Industrial or Commercial customer with large three phase loads. If the contract calls for 85% Power Factor, once the customer’s power factor falls below 85%, the Power Company bills the Customer according to the agreed penalty rates. Industrial loads are mostl...
read more
-
Jan 05,2021
Power factor correction capacitor banks and harmonic filters. Power factor correction capacitors and harmonic filters are an essential part of modern electric power systems. Power factor correction capacitors are the simplest and most economical means of increasing the capacity of any power system, minimizing energy losses and correcting load power factor. In addition, power factor penalties can b...
read more
-
Jan 27,2021
Overview ZDDQ Active Power Filter have exported to many countries all over the world. These filters are widely used in a number of industries such as oil & gas, manufacturing, water/wastewater, metal and mining, and paper and pulp. A harmonic filter is used to mitigate harmonics created by non-linear loads in electrical equipment. Classification Ⅰ. Product Insights Based on product type, ...
read more
-
Mar 04,2021
ZDDQ Active Harmonic Filter Active Harmonic Filter is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave, reactive power, and three-phase load unbalance. ZD-AHF-4 active harmonic filter is connected in parallel in 380V~456V power grid, to detect the harmonic wave in power grid in real time, generate the reverse-phase compensation current through the co...
read more
-
Mar 19,2021
Problems of Line Side Harmonics The two main line side harmonic concerns are the problems caused in the facility where they are being generated and the degree of harmonic infection passed to neighboring facilities. The degree of impact for either area depends on the number, size and frequency of use of all linear and non-linear loads . Mainly introduce harmoncs within a facility here. Within a fac...
read more
-
Mar 26,2021
Congratulations to the company for mentioning the new car Anhui Zhongdian Electric Co., Ltd., founded in 1988, is affiliated to the Design and Research Institute of the Ministry of Machinery Industry. It is a high-tech professional engaged in the R&D, production, sales and service of power quality equipment technology companies. The company passed the ISO9000 quality system certification in 20...
read more
-
May 18,2021
Harmonics and Active Power Filter In recent years, the use of non-linear load is increasing day by day. Non-linear loads such as traditional diode/ thyristor rectifiers with inductive load generate harmonic and reactive current, which leads to poor power factor, low energy efficiency, and harmful disturbance to other appliances. Also, in recent years, the large-scale use of the power electronic eq...
read more
-
Jun 24,2021
As an inexpensive source of reactive power, capacitor banks bring many benefits to a facility. They are widely deployed to avoid penalties on utility bills, lower distribution losses, increase transformer/Genset capacity, maintain nominal voltage, and to reduce energy losses resulting in decreased carbon emissions. When coupled with reactors, capacitor banks can filter harmonics generated by...
read more
-
Aug 09,2021
What Cause Power Quality Problems? Modern power electronics devices applications can improve our work more efficiency and make life easier, but at the same time they can pollute the power networks. Rectifiers play a large part in many applications that are growing faster than power system construction. Voltage and current harmonics, reactive power fluctuation, three phase unbalance, and other issu...
read more
-
Sep 07,2021
Formulas of Related Harmonics The following calculator computes the total harmonic current distortion (THDc or THDi), Peak Current, RMS Current, and Crest Factor based on individual harmonic current distortion values between the 1st and the 50th harmonic. Input the fundamental current and individual harmonic currents to compute THDc(THDi) also to view a waveform plot based on the input values. The...
read more
-
Oct 28,2021
ZDDQ-AHF Active Harmonic Filter ZDDQ Active Harmonic Filter(AHF) is used to improve Power Quality through autonomous detection and dynamic filtering of harmonic currents present in power grid. ZDDQ Active Harmonics Filter is a perfect comprehensive solution to power quality problems with power grid such as harmonic wave, reactive power, and three-phase load unbalance. ZD AHF is connected in parall...
read more