Jun 19,2020
Global compensation Where a load is continuous and stable, global compensation can be applied Principle The capacitor bank is connected to the busbars of the main LV distribution board for the installation, and remains in service during the period of normal load. Advantages The global type of compensation: Reactive current still flows in all conductors of cables leaving (i.e. downstream of) the ma...
read more
-
Oct 21,2020
Our Indian Clients and African Clients has installed hybrid reactive power compensation system. After our guide, they use ZDDQ SVG mixed with Capapacitor banks based on Contactors and Thyristors. A united system of thyristor switched capacitor (TSC) and static var generator (SVG) was proposed to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. Th...
read more
-
Nov 30,2020
Relations between Reactive power,power factor and penalty Power Factor penalty is spelled out in the contract between the Power Company and Industrial or Commercial customer with large three phase loads. If the contract calls for 85% Power Factor, once the customer’s power factor falls below 85%, the Power Company bills the Customer according to the agreed penalty rates. Industrial loads are mostl...
read more
-
Dec 09,2020
The static var generator (SVG) with appropriate control method is a good solution to solve the problem of reactive power impact and harmonic pollution which is generated by the nonlinear load. A control strategy using active current separation and the current indirect control is used for SVG. The active current separation is a method for detecting the harmonic and reactive current, and then the su...
read more
-
Dec 22,2020
SVG: Static Var Generator ANHUI ZHONGDIAN ELECTRIC CO., LTD. static var generator is a static electrical device/equipment/system that draws controlled capacitive or inductive current from the electrical power system and thereby generates or absorbs reactive power. Permanently connected and switchable reactor and capacitor banks have been always used in AC power systems to ensure desirable voltages...
read more
-
Dec 29,2020
The rising power consumption for the power quality equipment is the key driving factor for the market growth ZDDQ found according to the report: The global power quality equipment market size is projected to reach nearly USD 33.7 billion by 2028. Additionally, the market is forecasted to grow a CAGR of above 6.5% over the forecast period of 2020-2028. The key motivating force for the power efficie...
read more
-
Jan 05,2021
Research A recent ZDDQ survey shows that the global static VAR generator market is projected to grow remarkably owing to the persistent demand for stable power supply from the consumers. Knowing from Fortune Business Insights, in an upcoming report, titled, “Static VAR Generator“ Market Size, Share & Industry Analysis, By Type (Thyristor Based, MCR Based), By End-User (Electric Utility, Renewa...
read more
-
Jan 16,2021
Status analysis According to marketing research by ZDDQ(ANHUI ZHONGDIAN ELECTRC CO., LTD.). To reduce energy consumption and increase energy efficiency, many facility management executives are looking to renewable energy sources, such as solar or wind, to offset reliance on traditional electric power. Despite the growing prevalence of these solutions, there are drawbacks that can make alternative ...
read more
-
Feb 03,2021
HV/MV Power factor correction is directly related to the different aspects that assist the technical management of transport and distribution networks. These are: Power quality This involves the increase in the levels of voltage in substation busbars and line ends. Optimisation of the installation's cost of operation In other words, the decrease of the reactive energy and, therefore, the reduction...
read more
-
Mar 08,2021
High Voltage Power Capacitors Fields of Application INDIVIDUAL POWER FACTOR CORRECTION The power factor correction capacitor is connected directly to the terminals of the consumer and will be switched together with it. Advantages of individual capacitors at the load: • Complete control; capacitors cannot cause problems on the line during light load conditions • No need for separate switching...
read more
-
Mar 20,2021
A capacitor bank is a grouping of several identical capacitors interconnected in parallel or in series with one another. These groups of capacitors are typically used to correct or counteract undesirable characteristics, such as power factor lag or phase shifts inherent in alternating current (AC) electrical power supplies. FEATURES: Power factor correction by multi step design Standard & detu...
read more
-
Jul 22,2021
An example of how to calculate the capacity of reactive power (kVAr)? An Motor is supplying a load of 700 kW at a P.F (Power factor) of 0.65. What size of Capacitor in kVAr is required to raise the P.F (Power Factor) to unity (1)? And how many more kW can the motor supply for the same kVA loading when P.F improved. Supplying kW = 700 kW Original P.F = Cosθ1 = 0.65 Final P.F = Cosθ2 = 1 θ1 = C...
read more
-
Jan 20,2022
Static Synchronous compensator (STATCOM) is a fast-acting device capable of providing or absorbing reactive current and thereby regulating the voltage at the point of connection to a power grid. It is categorised under Flexible AC transmission system (FACTS) devices. The technology is based on VSCs with semi-conductor valves in a modular two-level configuration. ZDDQ Statcom have installed in many...
read more
-
Jun 30,2022
The benefits of power factor correction 1.Savings on the electricity bill Power factor correction eliminates penalties on reactive energy, decreases demand on kVA, and reduces power losses generated in the transformers and conductors of the installation. 2.Increased available power Fitting PFC equipment on the low voltage side increases the power available at the secondary of a MV/LV transformer. ...
read more
-
Aug 09,2022
ZDDQ-SVG Static Var Generator is an electronic reactive power compensation system, for both capacitive and inductive power. It has the same operating principle as an active filter; the SVG injects a current in the opposite direction to counteract the installation's non-useful power (inductive and capacitive), thus ensuring that the target cosϕ is achieved. ZDDQ SVG instantly compensates and adjust...
read more
-
Sep 08,2022
ZDDQ Low Voltage Capacitor Banks provide a cost-effective, user friendly, reliable solution for power factor correction. They are a more efficient alternative to individual motor capacitors, especially in large industrial facilities. ZDDQ Power Factor Correction Panels are designed to provide power factor correction with a single installation on the main plant bus and are ideal for applications wh...
read more
-
Dec 05,2022
Reactive Power in Inductive Loads Inductive loads such as chokes, motors, inductive heating equipment, generators, transformers, and arc welding equipment produce an electrical lag that is commonly referred to as inductance. This inductance causes a phase difference between current and voltage. As a result of phase shift due to inductance, there are times when current and voltage have different si...
read more
-
Mar 06,2023
ZDDQ Active Power Filters exported to Thailand. We have been cooperating with this customer for almost 3 years. The quality of our Active Power Filter is stable, the technical and market performance is excellent, the order demand of the customer is stable, and we have formed a relatively good reputation in the market. Thanks for Client's trust and support.Not more than 2 months, this new order is ...