-
Apr 29,2020
STATCOM A static synchronous compensator, known as a STATCOM, is another device used to regulate the power factor in medium to high voltage applications. They operate on roughly the same principles as a synchronous compensator, however, use a voltage source converter as opposed to a rotating machine to provide dynamic Power Factor Correction. STATCOMs use IGBT switching te...
read more
-
May 13,2020
High Power STATCOM in Electricity Networks A High Power STATCOM is usually installed to support electricity networks that have a poor power factor and often poor voltage regulation. STATCOM –static synchronous compensator – is a solution often deployed by utilities or large industries to solve flicker, harmonic and dynamic reactive compensation problems in medium voltage or high voltage netw...
read more
-
May 20,2020
STATCOM STATCOM (Static Synchronous Compensator)continuously provides variable reactive power in response to voltage variations, supporting the stability of the grid. STATCOM operates according to voltage source converter (VSC) principles, combining unique PWM (pulse width modulation) with millisecond switching. STATCOM functions with a very limited need for harmonic filters, contributing to a sma...
read more
-
Jun 29,2020
The nature of transformer inductive reactances All previous references have been to shunt connected devices such as those used in normal loads, and power factor correction capacitor banks etc. The reason for this is that shunt connected equipment requires (by far) the largest quantities of reactive energy in power systems; however, series-connected reactances, such as the inductive reactances of p...
read more
-
Jul 17,2020
Problem High Electricity Bills in Steel Factory. Analysis To analyze the power quality at Steels Factory and to understand the Voltage, Current, Power Factor, Active power,Reactive power, Apparent power, THD profile and to suggest the required solution to improve Power Factor, to qualify for Utility PF incentive. Towards fulfilling the need, fixed Capacitor bank of 2400KVAr has been installed at 1...
read more
-
Jul 27,2020
Overview ZD-MCJB Medium voltage automatic power factor controller and protection Unit Our R&D has developed MV automatic power factor controller and protection unit since May 2019, and has intalled in many sites an d has a very good running. Now we introduce our MV auto PF controller and protection unit officially. ZD-MCJB PF controller and protection unit is suitable for automatically adjusti...
read more
-
Sep 08,2020
Leading Provider of Technology One of the Leading Static Var Generator manufacturing base in China Exclusive to +/-100Mvar Statcom R&D manufacture Advanced and strong R&D center Patents Owner Based on IGBT National Industry standards drafters CE Certificate 101 national patens 1 national science and technology invention award Advanced Technologies Perfect Auto-diagnosis at Starting Stage D...
read more
-
Sep 15,2020
Leaders in Power Quality Solutions ZDDQ is one of leading manufacturers of power quality solutions from China. Here at ZDDQ we believe in creating and maintaining the highest quality power possible for our customers through an indepth understanding of power usage and electrical efficiencies. We source world’s best components to manufacture custom solutions to reduce maintenance and energy costs. N...
read more
-
Oct 04,2020
During 1st quarter in 2020, for the reason of Covid-19, Medium Voltage STATCOM projects are delayed or stopped in China. But from March, the conditions has been better and the projects status has been normal from the 2nd quarter. From the 2nd quarter to now,we have finished installatlion and commissioning of some Medium voltage Stacom projects, such as 10kv/4Mvar, 10kv/2Mvar, 35kv/12Mvar, 10k...
read more
-
Oct 30,2020
Our low voltage Static Var Generator has widely installed in many countries and has a good function and quality performance. In some countries, client use our SVG to compensate reactive power together with their capacitor banks, which is named as hybrid compensation system. In some countries, our SVG are used for power factor correction at the site where the load changes fast and frequently. And s...
read more
-
Nov 23,2020
ZDDQ Static Var Generator SVG and Active Power Filter APF adopt dual interface of Current Transformer,which has great to facilitate new project design and adaptation to old projects. Our SVG and APF can accurately calculate the load harmonic current data and provide perfect compensation effect. For following sites, Both single module or multiple modules in parallel, Multiple active filter/SVGcabin...
read more
-
Dec 09,2020
The static var generator (SVG) with appropriate control method is a good solution to solve the problem of reactive power impact and harmonic pollution which is generated by the nonlinear load. A control strategy using active current separation and the current indirect control is used for SVG. The active current separation is a method for detecting the harmonic and reactive current, and then the su...
read more
-
Dec 22,2020
SVG: Static Var Generator ANHUI ZHONGDIAN ELECTRIC CO., LTD. static var generator is a static electrical device/equipment/system that draws controlled capacitive or inductive current from the electrical power system and thereby generates or absorbs reactive power. Permanently connected and switchable reactor and capacitor banks have been always used in AC power systems to ensure desirable voltages...
read more
-
Dec 26,2020
Power factor is the percentage of consumed power(KW) versus supplied power(KVA). This is important because a low power factor can waste energy, result in inefficient use of electrical power, and often result in higher energy bills. Power Factor Correction will improve the energy efficiency of any electrical system, but a reduction in your power bill is only available where a power company charges ...
read more
-
Dec 29,2020
The rising power consumption for the power quality equipment is the key driving factor for the market growth ZDDQ found according to the report: The global power quality equipment market size is projected to reach nearly USD 33.7 billion by 2028. Additionally, the market is forecasted to grow a CAGR of above 6.5% over the forecast period of 2020-2028. The key motivating force for the power efficie...
read more
-
Jan 21,2021
ZDDQ Engineers give an example for reference, An Alternator is supplying a load of 650 kW at Power factor 0.65. What size of Capacitor banks (kVAR) is required to raise the Power Factor to unity (1 or >0.95)? And how many more kW can the alternator supply for the same kVA loading when P.F improved. Supplying kW = 650 kW Original P.F = Cosθ1 = 0.65 Final P.F = Cosθ2 = 1 θ1 = Cos-1 = (0.65) = 49°...
read more
-
Feb 02,2021
Harmonics in power system. In an electric power system, a harmonic is a voltage or current at a multiple of the fundamental frequency of the system, produced by the action of non-linear loads such as rectifiers, discharge lighting, or saturated magnetic devices. Harmonic frequencies in the power grid are a frequent cause of power quality problems. Harmonics in power systems result in increased hea...
read more
-
Feb 03,2021
HV/MV Power factor correction is directly related to the different aspects that assist the technical management of transport and distribution networks. These are: Power quality This involves the increase in the levels of voltage in substation busbars and line ends. Optimisation of the installation's cost of operation In other words, the decrease of the reactive energy and, therefore, the reduction...
read more