33kv statcom

Thyristor Switched Capacitor Banks TSC

ZDDQ low voltage automatic capacitor banks based on Thyristor(TSC) improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs.

Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring.

  • Brand:

    ZDDQ
  • item no.:

    ZD-DWJ-4-X/X
  • Payment:

    TT LC
  • product origin:

    China
  • Color:

    RAL7035
  • shipping port:

    Shanghai
  • Lead Time:

    15 days
  • Product Detail

Overview

ZDDQ Low Voltage Automatic Capacitor Banks based on Thyristor provide a cost-effective, user friendly, reliable solution for power factor correction. They are a more efficient alternative to individual motor capacitors, especially in large industrial facilities. ZDDQ units are designed to provide power factor correction with a single installation on the main plant bus and are ideal for applications where plant loading is constantly changing, resulting in the need for varying amounts of reactive power. The solid state reactive power controller reacts to a current signal from a single remote current transformer (customer's scope), measures plant power factor and adjusts system load requirements in selected kVAr steps in order to maintain the desired target power factor.

low voltage power factor correction panels        
SLD of automatic capacitor banks
  Metal closed capacitorf banks and harmonic filters    Three phase line diagram of capacitor banks and harmonic filters


Technical Data

Electrical Specification                                                                                   

Input Voltage Range 

AC 308V-480V

Electric Connection 

3P4W

Rated Frequency   

50Hz /60Hz+/- 10%

Rated Reactive Power Rating Per Cabinet

100~600kVar

Operating Mode

Automatic/ Manual

Step Composition

8421 BCD Code Professional Design

Capacitance tolerance

-5%~10%

Rated Insulation Voltage

690V

Rated Impulse withstand voltage

8kv

Maximum permanent current

Capacitor:1.8*In at 480V

Main Incomer protection

Circuit breaker Protection/Isolated Fuses Group

Breaking Capacity

Icu 50kA

Reactors Rate

7%

Control Technology                                                                                      

Human Machine Interface

ZD-MC Liquid Crystal Display(LCD) Screen

Control Type

Rotary handle

Step protection type

Over load, over voltage, short circuit, over temperature

Monitoring      

ZDDQ HMI Monitor Software

Communication   

RS232/485,USB

Physical Specification                                                                                   

Color

RAL 7035(Grey)

IP Grade of Cabinet

IP3X

Cooling method 

Intelligent forced air cooling

Noise Level    

< 65dB(A) @1m (Module) 

Dimension(W*D*H/mm)  

800*800*2000 or customerized

Weight(Kg)       

400kg

Entry

Bottom or Top

Environmental Requirement                                                                            

Mounting location

Indoor installation

Ambient Temperature

-10~50 ℃

Relative Humidity

 0~95%

Altitude 

≤ 2000m Rated Capacity,

>2000m (derating 1% per 100m)


General Characteristics

High rupturing capacity (HRC) fuses connected to a busbar system.

Contactors/Thyristors specially adapted to the work with capacitors.

Inrush current limiting inductances.

Fast discharge resistors.

Low losses power capacitors.

Reactive power controllers.

Terminals for neutral and ground conductors.

Metal cabinet containing all the switchgear.

960kvar thyrsitor switched capacitor banks
24 steps capacitor banks based on Thyristor
960Kvar TSC Panel   24 steps Thyristor Switched Capacitor Banks

Advantages

Equipments wired and tested at works, full finished and supplied with all control and safety devices.

Easy transportation and installation due to their light weigh.

Easy selection of the most appropriate cos φ to avoid penalty charges on tariffs.

Long life and high reliability, thank to the use of self-healing and low losses capacitors.

Wide range of power (from 10 to 1600 kvar) with standard equipments for immediate delivery.

Option of including various accessories.


Applicaitons 

ZDDQ Capacitor banks and harmonic filters are widely used for fluctuating loads such as motors, variable frequency drives, melting furnace from Steel Rolling mills,Chemical industry,Cement plant, Suger plant, Textile, Hospitals, Hotels, Building segment,Automobile industry,Oil and gas industry,public grid etc.









Send a Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
related products
Low voltage capacitors banks and harmonic filter

Capacitor banks and harmonic filters. Low voltage

ZDDQ low voltage automatic capacitor banks and Harmonic Filters improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring.
lv capacitor banks

low voltage automatic capacitor banks with filters

ZDDQ low voltage automatic capacitor banks with filters improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring by improving power factor and filtering harmmonics.
SVG power factor correction panel

300kvar power factor correcton Panel with static var generator

IGBT controled power factor correction panel based on Static var generator SVG is the new standard in reactive energy compensation. This power electronic current source is the accurate and highly reliable solution for today’s networks characterised by significant increase in harmonics, voltage variations caused by intermittent renewable sources connected to the network and voltage level due to the smart grid development. The DSP controlled IGBT topology enables a perfect compensation on each phase for both inductive and capacitive loads. It also correct phase unbalance where necessary. Immune to harmonics, resonance and voltage level, it offers a maintenance free solution reusable in any network configuration.
automatic capacitor banks

600kVAr Capacitor Banks

ZDDQ Low voltage metal enclosed capacitor and filter banks improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Low voltage metal enclosed capacitor and filter banks,equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring by power factor improvement and harmonics filtering.
 industrial power factor correction panel SVG

Low votlage industrial power factor correction panel SVG panel

IGBT controled power factor correction panel based on Static var generator SVG is the new standard in reactive energy compensation. This power electronic current source is the accurate and highly reliable solution for today’s networks characterised by significant increase in harmonics, voltage variations caused by intermittent renewable sources connected to the network and voltage level due to the smart grid development. The DSP controlled IGBT topology enables a perfect compensation on each phase for both inductive and capacitive loads. It also correct phase unbalance where necessary. Immune to harmonics, resonance and voltage level, it offers a maintenance free solution reusable in any network configuration.
automatic multi-step capacitor banks

Low voltage metal enclosed capacitor and filter banks

ZDDQ Low voltage metal enclosed capacitor and filter banks improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Low voltage metal enclosed capacitor and filter banks,equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring by power factor improvement and harmonics filtering.
LV automatic power factor correction

Low voltage automatic power factor correction panels

ZDDQ Low voltage automatic power factor correction panels improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring by improveing power factor and harmoncis filtering.
Lv pfi panel

low voltage power factor improvement panel

ZDDQ low voltage power factor improvement panels improves power factor in systems with variable energy demand and non-linear loads, therefore, with variable reactive load needs. Equipped with a power factor controller to regulate their automated operation and monitoring features, ZDDQ automatic capacitor banks remove power factor charges of the electricity bill and reduce the losses of electrical equipment and wiring by improving power factor and harmonics filtering.
Send a Message
welcome to zddq
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact