May 29,2024
Active filters and passive filters are two types of filters that are often used in electronic circuits. Although they can both be used to filter certain frequencies in electrical signals, there are some different differences between them. 1. Working Principle Passive filters mainly rely on passive components (such as capacitors, inductors, resistors, etc.) to filter signals. They can only process ...
read more
-
Jun 13,2024
When an oscillating system is subjected to periodic external force, the amplitude of the oscillation increases sharply when the frequency of the external force is the same as or very close to the natural oscillation frequency of the system. The frequency at which resonance occurs is called "resonance frequency". In electrical engineering, the resonance phenomenon of an oscillating circuit. The res...
read more
-
Jul 01,2024
First of all, the operation of inductive equipment must establish a magnetic field (such as a motor). Since the instantaneous start-up of large equipment requires the power grid to provide a large amount of Reactive Current to establish a magnetic field, the voltage of the system will be greatly reduced at the moment of equipment startup, causing other equipment to be protected or unable to operat...
read more
-
Jul 09,2024
In the power system, the on-site compensation of high-voltage motors should be invested when the voltage drops by more than 10%. 1. The role of on-site compensation of high-voltage motors The on-site compensation of high-voltage motors can effectively improve the power factor of the power system, reduce line losses, ensure the stable operation of the system voltage, and reduce energy consumption a...
read more
-
Jul 16,2024
STATCOM and Voltage Flicker Mitigation What is votlage flicker? Voltage flicker refers to the rapid and repeated fluctuations in the voltage level of a power supply, which can cause noticeable changes in the intensity of lighting and can affect the performance of other electrical equipment. These fluctuations can be annoying and may lead to operational issues in sensitive equipment Causes of Volta...
read more
-
Aug 09,2024
690V 3 phase 3 wire networks A 690V 3-phase 3-wire network refers to an electrical power distribution system that operates at 690 volts between each line conductor, without a neutral wire. This type of network is commonly used in industrial and commercial applications where the loads do not require a neutral connection or where power is distributed primarily to large motors, equipment, or machiner...
read more
-
Aug 28,2024
Medium voltage power factor correction Medium Voltage Power Factor Correction (MV PFC) involves the application of devices and systems designed to improve the power factor in medium voltage electrical networks, typically in the range of 1 kV to 35 kV. Power factor correction at medium voltage is crucial for enhancing the efficiency of electrical power distribution, reducing losses, and avoiding pe...
read more
-
Sep 02,2024
Dynamic reactive power compensation Dynamic Reactive Compensation refers to the real-time adjustment of reactive power in an electrical system to maintain optimal voltage levels, improve power factor, and enhance overall power quality. It is essential in modern power systems, particularly in environments where loads fluctuate rapidly or where maintaining a stable voltage is critical. 1. Understand...
read more
-
Sep 05,2024
Application of reactive power compensation device SVG: Power system: SVG can be used for reactive power compensation and voltage regulation of power system to improve the stability and reliability of power grid. It can help power system reduce power loss, improve voltage quality, and improve power factor and efficiency of power grid. Industrial field: SVG can be used for reactive power compensatio...
read more
-
Sep 11,2024
Selecting the capacity of the transformer is crucial, as it directly affects the stability, efficiency and safety of the power system. The appropriate transformer capacity can ensure that current and future load requirements are met, avoiding equipment damage and energy waste caused by overload or underload. The correct capacity selection helps optimize operating costs, extend equipment life, and ...
read more
-
Sep 24,2024
What is the reason of resonance in power networks? Resonance in power networks occurs when the inductive and capacitive elements of the system interact in a way that amplifies specific frequencies, leading to excessive voltage or current oscillations. Here are the primary reasons for resonance in power networks: 1. Impedance Matching Resonant Frequency: Every electrical circuit has a natural reson...
read more
-
Oct 27,2024
Active Load Balancer and Active Power Filter Active Load Balancers and Active Power Filters (APFs) are both power quality devices, yet they serve different roles within electrical networks. Here’s an overview of each, along with their similarities and distinctions: Active Load Balancer Function: Primarily used to ensure balanced loading across all three phases in a power system. Operation: Activel...
read more
-
Nov 13,2024
In the power supply system, reactive power compensation can improve the power factor of the power grid, reduce the loss of power transformers and transmission lines, and improve the power supply environment. Reasonable selection of compensation devices can minimize the loss of the power grid and improve the quality of the power grid. If the selection or use is improper, it may cause many problems ...
read more