-
Nov 22,2019
In an L.V/M.V/H.V electrical installation, capacitor banks (or Static var generator/Active harmonic filter)can be installed at 3 different levels. 1.Global installation Advantages: - No reactive energy bill. - Represents the most economical solution since all the power is concentrated at one point and the expansion coefficient makes it possible to optimize banks - Relieves the transformer. Remark:...
read more
-
Nov 21,2019
ZDDQ power quality correction products are part of the solution. Most utilities charge for peak electrical demand on each month’s electrical bill. The demand charge is to allow the utilities to recoup part of their capital investment in the distribution network they operate. Each customer pays a demand charge for its peak operating load. Often inherent in the structure of these demand charges is a...
read more
-
Nov 23,2019
Fundamental (component) The component of order 1 of the Fourier series of a periodic quantity. (IEV 161-02-17) Harmonic The component of the Fourier-series decomposition of a volt- age or current periodic wave. (IEV 161-02-18 modified) Harmonic order (h) The ratio of the frequency of a harmonic (fh) to the fundamen- tal (rated) network frequency (f1). (IEV 161-02-19 modified) Odd harmonics Harmoni...
read more
-
Nov 23,2019
Capacitor element Device consisting essentially of two electrodes separated by a dielectric (IEV 436-01-03). Capacitor unit Assembly of one or more capacitor elements in the same container with external terminals (IEV 436-01-04). Capacitor bank Multiple capacitor units connected so as to act together (IEV 436-01-06). Capacitor The word “capacitor” is used when it is not necessary to put particular...
read more
-
Nov 23,2019
var The unit of measurement for reactive power. Active power (P) Active power is the useful power that does the actual work. Active power is measured in W, kW, MW. Reactive power (Q) Reactive power is a product of an AC system. Reactive power is used to produce magnetic fields. Reactive power is mea- sured in var, kvar, Mvar. Apparent power (S) Apparent power or total power is a combination of act...
read more
-
Dec 23,2019
The Graph below shows Harmonic Current Distortion in the form of THDi. This is hovering between 20 and 25%. Ideally, it should be less than 10% and preferably less than 8% THDi. The highest value of average total harmonic distortion (THDi%) across three phases was calculated from raw data. This value is 24.19%THDi and was recorded at time shown. At the same time, average line current (Amps) across...
read more
-
Nov 22,2019
Based on the power of a receiver in kW, this table can be used to calculate the power of the capacitors to change from an initial power factor to a required power factor. It also gives the equivalence between cosΦ tanΦ,
read more
-
Sep 19,2019
Anhui Zhongdian(ZDDQ) Electric Co., Ltd. established in 2001. ZDDQ Technology Park locates in Bengbu City of Anhui Provice. We're a professional and leading manufacture, focus on advanced power quality solutions and power factor correction. APF,SVG,APFC are our main products. ZDDQ have a leading independent R&D team and quality supervision system, and maintain long-term cooperative relations w...
read more