Jul 01,2024
First of all, the operation of inductive equipment must establish a magnetic field (such as a motor). Since the instantaneous start-up of large equipment requires the power grid to provide a large amount of Reactive Current to establish a magnetic field, the voltage of the system will be greatly reduced at the moment of equipment startup, causing other equipment to be protected or unable to operat...
read more
-
Jul 09,2024
In the power system, the on-site compensation of high-voltage motors should be invested when the voltage drops by more than 10%. 1. The role of on-site compensation of high-voltage motors The on-site compensation of high-voltage motors can effectively improve the power factor of the power system, reduce line losses, ensure the stable operation of the system voltage, and reduce energy consumption a...
read more
-
Jul 16,2024
STATCOM and Voltage Flicker Mitigation What is votlage flicker? Voltage flicker refers to the rapid and repeated fluctuations in the voltage level of a power supply, which can cause noticeable changes in the intensity of lighting and can affect the performance of other electrical equipment. These fluctuations can be annoying and may lead to operational issues in sensitive equipment Causes of Volta...
read more
-
Jul 22,2024
Statcom, Current sampling and voltage sampling Current and Voltage Sampling in STATCOM Static Synchronous Compensator (STATCOM) is a device used for dynamic reactive power compensation and voltage stabilization in power systems. Accurate current and voltage sampling are crucial for the proper functioning of STATCOM, ensuring it provides the necessary reactive power compensation and voltage regulat...
read more
-
Jul 23,2024
UPS and Energy Storage Technology are two different power systems. Their main differences lie in their working principles, application scenarios, and energy storage methods. The main working principle of UPS is to convert the input AC power into DC power through power conversion circuits and batteries and other devices, and then convert it back to AC output through inverters. When the input power ...
read more
-
Jul 29,2024
The preventive measures for the capacity attenuation of power capacitors are crucial in the application of power capacitor banks. Here are some of the main preventive measures: Control operating conditions: Temperature control: Ensure that the capacitor operates within the temperature range recommended by the manufacturer. Excessive temperature will accelerate the aging of the internal materials o...
read more
-
Aug 09,2024
690V 3 phase 3 wire networks A 690V 3-phase 3-wire network refers to an electrical power distribution system that operates at 690 volts between each line conductor, without a neutral wire. This type of network is commonly used in industrial and commercial applications where the loads do not require a neutral connection or where power is distributed primarily to large motors, equipment, or machiner...
read more
-
Aug 10,2024
Capacitor Banks play an important role in power systems and are mainly used to provide reactive power compensation, improve voltage quality, and improve system stability. Capacitor banks can be divided into many types according to different classification standards. Here are some common capacitor bank types: 1. Classification by connection method Star-connected capacitor bank: The capacitor units ...
read more
-
Aug 19,2024
Response time of reactive power compensation product The response time of a reactive power compensation product refers to the time it takes for the device to detect a change in the reactive power demand and adjust its output accordingly to maintain the desired power factor or voltage level. This is a crucial performance metric for systems that require rapid compensation, such as those with dynamic...
read more
-
Aug 27,2024
Harmonic voltage and harmonic current are common phenomena in power systems, and they have a great impact on power equipment and power grid operation. Harmonics refer to voltage or current components whose frequencies are integer multiples of the fundamental frequency. In power systems, the fundamental frequency is generally 50Hz or 60Hz, so the harmonic frequency is an integer multiple of 50Hz or...
read more
-
Aug 28,2024
Medium voltage power factor correction Medium Voltage Power Factor Correction (MV PFC) involves the application of devices and systems designed to improve the power factor in medium voltage electrical networks, typically in the range of 1 kV to 35 kV. Power factor correction at medium voltage is crucial for enhancing the efficiency of electrical power distribution, reducing losses, and avoiding pe...
read more
-
Sep 02,2024
Dynamic reactive power compensation Dynamic Reactive Compensation refers to the real-time adjustment of reactive power in an electrical system to maintain optimal voltage levels, improve power factor, and enhance overall power quality. It is essential in modern power systems, particularly in environments where loads fluctuate rapidly or where maintaining a stable voltage is critical. 1. Understand...
read more
-
Sep 05,2024
Application of reactive power compensation device SVG: Power system: SVG can be used for reactive power compensation and voltage regulation of power system to improve the stability and reliability of power grid. It can help power system reduce power loss, improve voltage quality, and improve power factor and efficiency of power grid. Industrial field: SVG can be used for reactive power compensatio...
read more
-
Sep 10,2024
What is the relation of Static var generator and Carbon reduction? Static Var Generator (SVG) plays a significant role in reducing carbon emissions by improving the efficiency of electrical systems. Here's how SVGs contribute to carbon reduction: 1. Improved Power Factor SVG help improve the power factor of an electrical system by providing reactive power compensation. A low power factor leads to ...
read more
-
Sep 11,2024
Selecting the capacity of the transformer is crucial, as it directly affects the stability, efficiency and safety of the power system. The appropriate transformer capacity can ensure that current and future load requirements are met, avoiding equipment damage and energy waste caused by overload or underload. The correct capacity selection helps optimize operating costs, extend equipment life, and ...
read more
-
Oct 08,2024
Static Var Generator (SVG) modules and panels are essential components in reactive power compensation systems, designed to improve power quality and stabilize voltage in electrical networks. Here's an overview of both: 1. SVG Modules Function: These are the core components responsible for providing dynamic reactive power compensation by injecting or absorbing reactive power in response to varying ...
read more
-
Oct 14,2024
Low-voltage capacitor cabinets are electrical equipment used in power systems. Their main function is to compensate the power factor of the power system and improve the power supply quality of the system. When installing low-voltage capacitor cabinets, the following aspects need to be noted: Installation location selection: Low-voltage capacitor cabinets should be installed in ventilated, dry, non...
read more
-
Oct 22,2024
SVG (Static Var Generator) plays a vital role in photovoltaic power stations. It significantly improves the energy efficiency, grid stability and power quality of photovoltaic power stations by quickly and accurately providing or absorbing reactive power. SVG is an advanced reactive power compensation device that uses power electronics technology to achieve rapid regulation of grid reactive power....
read more