Nov 17,2023
ZDDQ, a professional manufacturer of power factor correction and harmonic mitigation field since 2001. Today let's talk about power factor correction and energy saving. Power factor correction (PFC) is a technique used to improve the power factor of electrical systems. The power factor is a measure of how effectively the current is being converted into useful work in an AC electrical system. A low...
read more
-
Nov 25,2023
ZDDQ is committed to the power quality industry, keeping up with the development of the field, and is now cooperating with FGI on the energy storage industry (ESS). An energy storage system (ESS) is a technology that stores excess electrical energy and releases it when needed. It helps to enhance the reliability, stability, and efficiency of electrical power systems by addressing the intermittency...
read more
-
Dec 02,2023
ZD-GWJ Medium Voltage(3kV~24kV) group automatic reactive power compensation device automatically switches capacitor banks according to the voltage and reactive power of the power supply bus, and performs reactive power compensation by tracking load changes, thereby providing power factor, improving power supply quality, and reducing power consumption. It is often installed in front of the control ...
read more
-
Jan 19,2024
Power Factor Control refers to the management and maintenance of an acceptable power factor in electrical systems. Power factor is the ratio of real power (kW) to apparent power (kVA) in an electrical circuit. A low power factor indicates that the circuit is inefficient and requires more current to deliver a given amount of power. This results in increased energy losses, higher electricity bills, ...
read more
-
Jan 29,2024
To build a capacitor bank panel, you will need to follow these general steps: Determine the capacitor bank size: Calculate the required capacitance based on the power factor correction needs of your system. Consider factors such as the target power factor, load characteristics, and voltage levels. Select capacitors: Choose high-quality capacitors that are suitable for the desired voltage and curre...
read more
-
Feb 26,2024
A Static Synchronous Compensator (STATCOM) is a power electronic device used for voltage control and reactive power compensation in electrical power systems. It is typically connected to the grid and is capable of injecting or absorbing reactive power to regulate the system voltage. The control of voltage by a STATCOM is primarily achieved by manipulating its reactive power output. Here's a basic ...
read more
-
Mar 20,2024
Urban rail transit systems mainly include: subway systems, light rail systems, monorail systems, trams, maglev systems, automatic guide rail systems, and urban rapid rail systems. According to the different nature of electricity consumption, the power supply system of the subway system is mainly divided into two, one is the traction power supply system and the other is the power lighting power sup...
read more
-
Mar 25,2024
Static Synchronous Compensator (STATCOM) is a device used in power systems to control voltage and reactive power. In the context of rail transit, STATCOM can serve several purposes: Voltage Regulation: STATCOM can regulate the voltage levels in the rail transit system, ensuring that they remain within acceptable limits. It can compensate for voltage drops or fluctuations caused by various factors ...
read more
-
Apr 01,2024
Energy storage has significant potential and offers several opportunities in various sectors. Here are some key chances associated with energy storage: Renewable Energy Integration: Energy storage can facilitate the integration of renewable energy sources like solar and wind power by storing excess electricity generated during periods of high production and supplying it during times of low product...
read more
-
Apr 17,2024
1. What is reactive power? In the operation of the power grid, due to the existence of current and voltage, there is not only active power but also reactive power in the power system. Active power is the part of electrical energy that is directly converted into efficiency, such as the process in which electrical energy driving motors, heaters and other loads is converted into mechanical energy and...
read more
-
Jul 01,2024
First of all, the operation of inductive equipment must establish a magnetic field (such as a motor). Since the instantaneous start-up of large equipment requires the power grid to provide a large amount of Reactive Current to establish a magnetic field, the voltage of the system will be greatly reduced at the moment of equipment startup, causing other equipment to be protected or unable to operat...
read more
-
Jul 09,2024
In the power system, the on-site compensation of high-voltage motors should be invested when the voltage drops by more than 10%. 1. The role of on-site compensation of high-voltage motors The on-site compensation of high-voltage motors can effectively improve the power factor of the power system, reduce line losses, ensure the stable operation of the system voltage, and reduce energy consumption a...
read more
-
Jul 16,2024
STATCOM and Voltage Flicker Mitigation What is votlage flicker? Voltage flicker refers to the rapid and repeated fluctuations in the voltage level of a power supply, which can cause noticeable changes in the intensity of lighting and can affect the performance of other electrical equipment. These fluctuations can be annoying and may lead to operational issues in sensitive equipment Causes of Volta...
read more
-
Jul 23,2024
UPS and Energy Storage Technology are two different power systems. Their main differences lie in their working principles, application scenarios, and energy storage methods. The main working principle of UPS is to convert the input AC power into DC power through power conversion circuits and batteries and other devices, and then convert it back to AC output through inverters. When the input power ...
read more
-
Aug 28,2024
Medium voltage power factor correction Medium Voltage Power Factor Correction (MV PFC) involves the application of devices and systems designed to improve the power factor in medium voltage electrical networks, typically in the range of 1 kV to 35 kV. Power factor correction at medium voltage is crucial for enhancing the efficiency of electrical power distribution, reducing losses, and avoiding pe...
read more
-
Sep 02,2024
Dynamic reactive power compensation Dynamic Reactive Compensation refers to the real-time adjustment of reactive power in an electrical system to maintain optimal voltage levels, improve power factor, and enhance overall power quality. It is essential in modern power systems, particularly in environments where loads fluctuate rapidly or where maintaining a stable voltage is critical. 1. Understand...
read more
-
Sep 11,2024
Selecting the capacity of the transformer is crucial, as it directly affects the stability, efficiency and safety of the power system. The appropriate transformer capacity can ensure that current and future load requirements are met, avoiding equipment damage and energy waste caused by overload or underload. The correct capacity selection helps optimize operating costs, extend equipment life, and ...
read more
-
Nov 13,2024
In the power supply system, reactive power compensation can improve the power factor of the power grid, reduce the loss of power transformers and transmission lines, and improve the power supply environment. Reasonable selection of compensation devices can minimize the loss of the power grid and improve the quality of the power grid. If the selection or use is improper, it may cause many problems ...