Mar 25,2024
Photovoltaic power generation, as a new and pollution-free power generation method today, has greatly alleviated the demand for traditional electric energy. However, for the grid-connected photovoltaic power generation system, due to its inherent randomness, volatility, and intermittent characteristics, and the grid-connected photovoltaic power generation system contains a large number of nonlinea...
read more
-
Apr 17,2024
1. What is reactive power? In the operation of the power grid, due to the existence of current and voltage, there is not only active power but also reactive power in the power system. Active power is the part of electrical energy that is directly converted into efficiency, such as the process in which electrical energy driving motors, heaters and other loads is converted into mechanical energy and...
read more
-
Apr 25,2024
To connect a Static Synchronous Compensator (STATCOM) to a high voltage system, you need to follow a series of steps and ensure compliance with safety regulations: System Design: Determine the appropriate rating and configuration of the STATCOM based on the requirements of the high voltage system. Consider factors such as voltage level, reactive power compensation, and system stability. Equipment ...
read more
-
May 05,2024
To realize the connection of a Static Synchronous Compensator (STATCOM) to a high voltage system and address negative sequence compensation, you need to follow certain steps: Determine the system requirements: Assess the voltage levels, power ratings, and control requirements of your high voltage system. Understanding the specific needs will help you design and configure the STATCOM accordingly. C...
read more
-
Jun 03,2024
33kV Capacitor Banks Static Reactive Power Compensation: Capacitor banks provide fixed reactive power compensation. Simple Technology: Consists of capacitors connected in series or parallel to provide reactive power. Advantages: Cost-Effective: Typically less expensive than STATCOM, making them a cost-effective solution for reactive power compensation. Simplicity: Easier to install and maintain du...
read more
-
Jul 01,2024
First of all, the operation of inductive equipment must establish a magnetic field (such as a motor). Since the instantaneous start-up of large equipment requires the power grid to provide a large amount of Reactive Current to establish a magnetic field, the voltage of the system will be greatly reduced at the moment of equipment startup, causing other equipment to be protected or unable to operat...
read more
-
Jul 09,2024
In the power system, the on-site compensation of high-voltage motors should be invested when the voltage drops by more than 10%. 1. The role of on-site compensation of high-voltage motors The on-site compensation of high-voltage motors can effectively improve the power factor of the power system, reduce line losses, ensure the stable operation of the system voltage, and reduce energy consumption a...
read more
-
Jul 16,2024
STATCOM and Voltage Flicker Mitigation What is votlage flicker? Voltage flicker refers to the rapid and repeated fluctuations in the voltage level of a power supply, which can cause noticeable changes in the intensity of lighting and can affect the performance of other electrical equipment. These fluctuations can be annoying and may lead to operational issues in sensitive equipment Causes of Volta...
read more
-
Jul 22,2024
Statcom, Current sampling and voltage sampling Current and Voltage Sampling in STATCOM Static Synchronous Compensator (STATCOM) is a device used for dynamic reactive power compensation and voltage stabilization in power systems. Accurate current and voltage sampling are crucial for the proper functioning of STATCOM, ensuring it provides the necessary reactive power compensation and voltage regulat...
read more
-
Aug 19,2024
Response time of reactive power compensation product The response time of a reactive power compensation product refers to the time it takes for the device to detect a change in the reactive power demand and adjust its output accordingly to maintain the desired power factor or voltage level. This is a crucial performance metric for systems that require rapid compensation, such as those with dynamic...
read more
-
Aug 28,2024
Medium voltage power factor correction Medium Voltage Power Factor Correction (MV PFC) involves the application of devices and systems designed to improve the power factor in medium voltage electrical networks, typically in the range of 1 kV to 35 kV. Power factor correction at medium voltage is crucial for enhancing the efficiency of electrical power distribution, reducing losses, and avoiding pe...
read more
-
Sep 02,2024
Dynamic reactive power compensation Dynamic Reactive Compensation refers to the real-time adjustment of reactive power in an electrical system to maintain optimal voltage levels, improve power factor, and enhance overall power quality. It is essential in modern power systems, particularly in environments where loads fluctuate rapidly or where maintaining a stable voltage is critical. 1. Understand...
read more
-
Sep 05,2024
Application of reactive power compensation device SVG: Power system: SVG can be used for reactive power compensation and voltage regulation of power system to improve the stability and reliability of power grid. It can help power system reduce power loss, improve voltage quality, and improve power factor and efficiency of power grid. Industrial field: SVG can be used for reactive power compensatio...
read more
-
Sep 10,2024
What is the relation of Static var generator and Carbon reduction? Static Var Generator (SVG) plays a significant role in reducing carbon emissions by improving the efficiency of electrical systems. Here's how SVGs contribute to carbon reduction: 1. Improved Power Factor SVG help improve the power factor of an electrical system by providing reactive power compensation. A low power factor leads to ...
read more
-
Sep 11,2024
Selecting the capacity of the transformer is crucial, as it directly affects the stability, efficiency and safety of the power system. The appropriate transformer capacity can ensure that current and future load requirements are met, avoiding equipment damage and energy waste caused by overload or underload. The correct capacity selection helps optimize operating costs, extend equipment life, and ...
read more
-
Sep 24,2024
What is the reason of resonance in power networks? Resonance in power networks occurs when the inductive and capacitive elements of the system interact in a way that amplifies specific frequencies, leading to excessive voltage or current oscillations. Here are the primary reasons for resonance in power networks: 1. Impedance Matching Resonant Frequency: Every electrical circuit has a natural reson...
read more
-
Oct 08,2024
Static Var Generator (SVG) modules and panels are essential components in reactive power compensation systems, designed to improve power quality and stabilize voltage in electrical networks. Here's an overview of both: 1. SVG Modules Function: These are the core components responsible for providing dynamic reactive power compensation by injecting or absorbing reactive power in response to varying ...
read more
-
Oct 22,2024
SVG (Static Var Generator) plays a vital role in photovoltaic power stations. It significantly improves the energy efficiency, grid stability and power quality of photovoltaic power stations by quickly and accurately providing or absorbing reactive power. SVG is an advanced reactive power compensation device that uses power electronics technology to achieve rapid regulation of grid reactive power....